OPERATION
Switch off the LED fog machine and disconnect it from the power supply before filling the container! Fill the container of the LED fog
machine only with Cameo fog fluid (preferably Cameo Fast Fluid) and close it carefully. The fog machine is ready for operation a few minutes
after switching on (approx. 5 minutes). It features a canister light (LED) and a 4-digit LED display to provide information on the operating
status. Display elements canister light and display are activated in the factory settings.
1. During warm-up phase of the evaporator, the canister is permanently lit up in red, the display shows "uP" and the device is not ready for
operation.
2. Whilst ready for operation, the canister is constantly lit blue, and depending upon settings, the display will show either "rEAd" (control via
cable remote control), or the currently configured DMX start address (control via DMX controller).
3. If the fog fluid in the container is all used up, the canister light will start to flash red after approximately 2 minutes, two minus symbols
will be shown in the display and the LED fog machine will switch to error mode. Switch off the unit and disconnect it from the mains. Fill the
container with fog fluid and switch the unit back on. Follow the same procedure if you notice that the fluid has all been used before the fog
machine switches to error mode.
If there is a DMX signal to the device, the DMX mode is activated automatically and the currently configured DMX start address will appear
in the display. The cable remote control is disabled in this case. If there is no DMX signal, the LED fog machine can be controlled with the
supplied cable remote control.
The evaporator is
LED fog machine ready (ready).
Control via cable remote control.
CONFIGURE DMX START ADDRESS
Press the MODE button repeatedly until "Addr" appears in the display. Now press ENTER and configure the DMX start address using the UP
and DOWN buttons as required (001 - 509). Confirm your entry with ENTER.
-> ENTER ->
ADJUSTMENT OF DISPLAY ELEMENTS
In some cases, canister lighting and LED display can have a disturbing effect and can therefore be switched off (the empty canister warning
is excluded and will be activated in the event of an error).
Press the MODE button repeatedly until the display shows "dArk", press ENTER and select the desired setting using the UP and DOWN buttons
(on = container lighting switched off, display switched off after approx. 15 seconds / oFF = container lighting and display permanently active).
Confirm your entry with ENTER.
-> ENTER ->
CABLE REMOTE CONTROL
1
INTERVAL
Interval function for fog output and simultaneous illumination of LEDs. Press the button to start the interval function and again to quit. The
fog burst and LED illumination period is approximately 2 seconds. Configure the time interval between bursts with the TIME dial. If the
interval function is activated, the indicator LED on the button is lit. During fog bursts, "FoG" appears on the display.
6
-
UP/DOWN
/
UP/DOWN
2
1
LED fog machine ready,
DMX signal is present.
-> ENTER
<- MODE
-> ENTER
<- MODE
4
6
3
5