Trouble Shooting
Fault
Indicator Light does not
come on &
Merchandiser does not
heat up
Indicator Light comes on
but Warmer does not heat
up
Lamp does not light when
switched on.
Technical Specifications
Voltage
Code
(Volts)
CK627
230V/50Hz
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a
13amp fuse.
The plug is to be connected to a suitable mains socket
The appliance is wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit
If in doubt, consult a qualified electrician
Electrical isolation points must be kept clear of any obstructions. In the event of
any emergency
disconnection being required they must be readily accessible
Probable Cause
Power is not switched at
socket
Plug fuse has failed
Power cable is damaged
Thermostat has failed
Heating element has failed Call BUFFALO dealer for
Thermostat has failed
Power is not switched on
at socket.
Lamp has failed.
Power
Current
(Watts)
(Amps)
800w
3.7
Action Required
Turn power on at socket
Change fuse
Call BUFFALO dealer for
repair service
Call BUFFALO dealer for
repair service
repair service
Call BUFFALO dealer for
repair service
Turn power on at socket
and rear of
Merchandiser
Replace lamp, call
BUFFALO dealer for
replacement.
Dimensions
(mm)
785 x 460 x 448mm
Weight
(Kgs)
22