Pressure
______ ______ min. 1,4 bar (20 psi)
Flush water flow
____ _____ 12 lpm about (3,2 gpm abt.)
System operating pressure ____ _____ 6 - 7 bar (90-100 psi) abt.
Wastewater flow
____ _____ 3 lpm abt. (0,8 gpm abt.)
Wastewater TDS
____ _____
Pure water flow
____ _____ 4 - 5 lpm abt. (1,20 gpm abt.)
abt.)
Pure water TDS
______ ______ Less than 10 ppm for all machines.
Identify the parameters that are outside of the normal range and use the information in the following troubleshooting matrix to
correct the situation.
If after performing all tests and working through the matrix, you still have operational issues, please fill out this form completely
before contacting service centre. This information is required for proper evaluation of the system.
Dimensions
Weight (Without Filters)
Power supply.
Water Pressure.
Pure Water production.
Waste water production.
Stream of water maximun
height.
Pump Unit System.
SCRAPPING
If you decide to stop using the equipment, you should render it
inoperative by removing the electric power cable. Parts which
might constitute a danger, especially to children playing with
the appliance, should be made harmless.
The equipment is classified as special waste. It must be taken
apart and divided into uniform sections which should be dis-
posed off according to current legislation.
Do not use the components removed as spare parts.
BATTERIES
Considering the danger of some components, it is advisable
to take them to an authorized collection and disposal center.
With Electric Motor Unit
TECHNICAL CHARACTERISTICS
Without Pump Unit
50 cm (20")x53 cm
(21")x127 cm (50")
23 kg, (50 lbs)
-
Water Pressure supply
1,5 - 2,5 lpm ( 0,40 - 0,7
gpm) Medium
2 lpm (0,53 gpm) abt.
Depending on tap water
pressure maximum about 10
m (33 ft) with one pole.
English
With Battery Pump Unit
4 - 5,5 lpm about (1,25 gpm abt.)
4 - 5 bar (60-75 psi) abt.
2 lpm abt. (0,5 gpm circa)
2 - 3,5 lpm abt. (0,75 gpm abt.)
With Electric Motor Unit
50 cm (20")x53 cm
(21")x127 cm (50")
43 kg, (95 lbs)
1ac 230V 50Hz
About 6 - 7 bar (90 - 100 psi)
5 lpm (1,32 gpm) med.
3 lpm (0,80 gpm) abt.
20 m (65 ft) with 2 poles
Motor
LEESON
0,37 kw a 1725/1425 rpm,
50/60 hz, 115/110V - 208V
- 220/230V, Pump FLUID-
O-TEC type PO/PA 70-400
max 16 bar, da 70 a 400 lpm
a 1450 rpm.
TROUBLESHOOTING
Problem
Electric motor does not start.
Remedy
Check outlet to ensure it has live power.
Remove extension cord(s) if being used. Plug the machine
directly into outlet.
Test and reset the machine.
Unplug the machine and check cord wire connections.
Inspect cord for damage.
Contact the service centre.
Problem
Low supply water flow or pressure.
Remedy
Eliminate all extension hoses and connect directly to spigot with
- 19 -
Without Pump Unit.
4 lpm ca. (1,1 gpm abt.)
2 - 3 bar abt. (30-45 psi)
(see supply water press.)
1,8 lpm ab. (0,4 gpm ab.)
1,5 - 2,5 lpm abt. (0,5 gpm
With Battery Unit
50 cm (20")x53 cm
(21")x127 cm (50")
29 kg, (86 lbs)
cc 12V 33Ah
About 4 - 5 bar (60 - 75 psi)
2 - 3,5 lpm (0,53 - 0,93 gpm)
med.
2 lpm (0,53 gpm) abt.
20 m (65 ft) with 1 pole
1/2CV,
Battery 12 V 33 Ah
motor type SHURFLO
Pump SHURFLO 12V CC,
6,4 lpm, 7 A.
Battery Charger: 12 V 4 A.

Publicité

loading

Produits Connexes pour IPC Eagle APTA40016

Ce manuel est également adapté pour:

Highpure hp bHighpure hp eHighpure hp 0