PROLUMIA LED PRO-AQUA II + Manuel D'utilisation page 8

Masquer les pouces Voir aussi pour LED PRO-AQUA II +:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MICROWAVE SENSOR - PARAMETER SETTINGS
Detection Area
This determines the effective range of the motion detector and is set
with DIP switches on the sensor, please see figure below. Note that
reducing the sensitivity will also narrow the detection range.
Hold time orientation lighting
During this period, the fixture will light up at low level (20%). When
this is set to +∞, the fixture gives permanent 20% light when no
movement detected. It is set with DIP switches on the sensor, please
see figure below.
Daylight 2
This is only applicable under mode 2.
Under this daylight level the fixture will light at low level.
8
Hold Time
This determines the time the fixture remains at 100% and is set with
DIP switches on the sensor, please see figure below. The walk test
(5s) setting is useful when installing the fixture to establish correct
operation and range.
Daylight 1
This allows the sensor to switch the unit on when daylight level is
either full daylight (15Lux), low daylight (10Lux),or after dark (5Lux). It
also allows the sensor to be disabled. As long as the light level is above
the set point, the fixture will stay off when motion is detected.
Mode
Mode 1: Fixture remains off during motion if the daylight level is
above the value set at "Daylight 1".
Mode 2: When the daylight level falls below the value set under
"Daylight 2", the fixture will light at low level. When motion is detected,
it is shifting to 100%.
www.prolumia.eu

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Led pro-aqua ii high power

Table des Matières