SET UP CONTINUED
2.2 CONNECTION FOR NATURAL GAS
The flex line that runs from the gas valve to the burner has
been connected at the factory. You will only need to connect
the natural gas line from the gas valve to the gas source, as
shown in Figure E.
Perform a leak test before you replace the burner plate. (See
step 3.)
Connect to the gas source.
3
P E R F O R M A L E A K T E S T
Perform a leak test at least once a year whether the gas
supply cylinder has been disconnected or not. In addition,
whenever the gas cylinder is connected to the regulator or
whenever any part of the gas system is disconnected or
replaced, perform a leak test.
DANGER: Do not use fire table if there is evidence of
leaking gas. If a leak is suspected, turn off main gas
supply immediately.
As a safety precaution, remember to always leak test
your fire table outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while
doing a leak test. Do not use a flame, such as a lighted
match, to test for leaks. Use a solution of soapy water.
1. Prepare a leak testing solution of soapy water by
mixing in a spray bottle one part liquid soap to one
part water.
2. Make sure all the control knobs are in the OFF
position.
3. Turn on the gas.
4. Apply the leak-testing solution by spraying it on joints
of the gas delivery system. Blowing bubbles in the
soap solution indicates that a leak is present.
INLET
FIGURE E
5. Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement part
recommended by the manufacturer. Do not attempt to
repair the cylinder valve if it is damaged. The cylinder
must be replaced.
6. Turn the control knob back to the full OFF position
If you are unable to stop a leak:
7. Turn the control knob back to the full OFF position.
8. Shut off the gas supply to the fire table and release
pressure in the hose and manifold.
9. On propane systems, remove the cylinder from the
fire table.
10. Call an authorized gas appliance service technician or
an liquid propane gas dealer.
Do not use the appliance until the leak is corrected.
1 1