Run-Vacuum
Product outlet full
Voltage presence
Circuit breaker guard
Filter Cleaning
Reset
Safety devices reset
Exchanger
Container outlet
Silo-hopper outlet
Separator full
Phase sequence
Silo-hopper full
Silo-hopper
Overtemperature
Start
Stop
11
Emergency stopping
Turn the switch to "0" to turn off the machine.
Operation
Figure 7
Vacuum gauge (2): green zone (3), red zone (1)
When using the machine, check the flow control:
■
when the machine is operating, the pointer of the vacuum
gauge must remain in the green zone (3) to ensure that
the speed of the intake air does not drop below the safety
value of 20 m/sec;
■
If the pointer is in the red zone (1) it means that the speed
of the air in the vacuum hose is less than 20 m/s, and that
the machine is not operating in optimal conditions. Shake
or replace the filter.
■
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
CAUTION!
The air speed in the vacuum hose must not be less than
20 m/s.
Condition indicated by the vacuum gauge pointer in the
green zone (3).
CAUTION!
All machines can be used only with hoses whose
diameters comply with the specifications in the
"Technical Data" table.
CAUTION!
Consult the "Troubleshooting" chapter if faults occur.
At the end of a cleaning session
■
Turn off the machine and remove the plug from the socket.
■
Wind up the connection cable.
■
Empty the container and clean the machine as described
in the "Maintenance, cleaning and decontamination"
paragraph.
■
Wash the container with clean water if aggressive
substances have been vacuumed.
■
Store the machine in a dry place, out of reach of
unauthorised people.
■
Lock the castor brakes.
■
During transport and when not using the machine, close
the vacuum inlet with the relevant plug (if equipped).