• Re-apply mains power to the device.
Configuration
6.
• To configure the detector settings, turn switch LUX (C) clockwise till the end and switches SENS (A)
and TIME (B) counter clockwise till the end. These switches are located at the bottom of the detector
• First set the detection field by moving the detector up-down and/or left-right. Walk around in the
detection field to determine the boundaries.
• Configure the speed with which movements are detected, by turning the movement sensitivity switch
(A) clockwise. Test by walking through the detection field at different speeds.
• Configure the time that the halogen spot has to be operational after detecting movement by turning
the time switch (B) clockwise.
• For the setting of the light sensitivity, turn the light sensitivity switch (C) counter clockwise till the end
(towards moon). Wait until darkness sets in, and at the preferred light condition, turn the light
sensitivity switch (C) clockwise while creating movement in the detection field until the spot switches
on.
7.
Service
• There are no user-serviceable parts.
• Contact your dealer for spare parts if necessary.
8.
Technical specifications
Lamp
IR detector
Use this device with original accessories only. Velleman nv cannot be held responsible in
the event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product, please visit our website www.perel.be. The information in this
manual is subject to change without prior notice.
00 (23/06/2010)
A.
B.
C.
max. voltage
maw. power
Detection angle
Detection distance
working temperature
Time delay
Installation height
EHS150DC
Movement sensitivity switch
Time switch
Light sensitivity switch
230V
AC
150W
180°
10 ± 2m
-10°C ~+40°C
10±5s ~ 7±1min (adjustable)
2 ~ 4.5m
4