Tip for the door open alarm
If the refrigerator door has been open for 120 seconds, you will hear an
alarm beep every 2 seconds until the door is closed. Press any button to
mute the door open alarm.
•
Non-volatile settings memory during power outages and default set-
tings.
1. User setting will not be lost during a power outage. When power is
restored all user settings will be unchanged.
2. When you turn on the appliance for the first time, the default tem-
perature setting is -18°C.
3. Settings such as temperature and all previously active additional
functions are stored in the memory.
•
High temperature alert
When the temperature in the refrigeration chamber is above -8°C for 6
hours, the high temperature alert will sound. The beep will sound inter-
mittently and the temperature display area will show an error code (E9).
The audible alert will stop when the temperature in the chamber drops
below -12°C.
Press any button to mute the audible alert. The error code will disappear
once the cause has been remedied.
•
Error Codes
Error code
Note
E1 / E2
Refrigeration chamber temperature sensor fault
E4 / E5
Defrost sensor fault
E7
Ambient temperature sensor fault
E6
Communication error
E9
High chamber temperature alert
EC / EC
Failure: EEPROM
Note: You can clear the error message by pressing any button. When a
fault occurs, priority is given to displaying the error code until the fault
is removed. If the error code is displayed despite attempts to clear it,
please contact the service.
•
Force defrost
To turn on force defrost simultaneously press and hold the tempera-
ture setting buttons
is activated, the appliance will stop refrigeration immediately. In this
mode, only the frost - free system heater operates. To turn off force de-
frost, simultaneously press and hold the temperature setting buttons
C and
D for 3 seconds.
C and
D for 3 seconds. When forced defrost
- 19 -