Assembly Instructions
1.
Remove machine from carton and inspect for
any visual damage.
2.
Remove parts inside the machine.
3.
Thread the flexible metal "gooseneck" fluid outlet
tube onto the pump outlet fitting (Fig. a).
4.
Place the parts cleaning tray over the ledges on
the walls of the tub. Make sure the nozzle of the
flexible metal "gooseneck" fluid outlet tube is
shaped to be facing in and downward toward the
center of the tub (Fig. b).
5.
Fill unit with suitable, water-based degreasing
solution sufficiently to cover the entire pump
(approximately 1.5 gallons) (Fig. c).
Important notes:
-
Follow degreasing solution mixing, usage and
safety label instructions carefully before using.
-
Be sure the cleaning solution level fully covers
the pump or it will not function properly.
6.
Plug power cord into an approved, grounded
and GFI equipped 120 Volt AC, 60 Hz outlet.
7.
Turn power switch to the "on" position. The parts
washer is now ready for use.
Overall Dimensions
Working Capacity
Maximum Pump Output Through Spigot
Electrical Requirements
Product Weight
Do not fill to maximum capacity. Fill only to working capacity of 3.5 gallons.
Fig. A
Fig. B
Fig. C
18-3/16" x 13-3/8" x 21-1/2"
3.5 gallons (13.3 litres)
15 litres/min.
115 Volt / 60 Hz / 0.5 Amp
17 lb (7.7 kg)
5