SAFETY
If the generator should malfunction, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock.
DANGER
Improper grounding can result in risk of electrocution.
Check with a qualified electrician for your local
requirements if you are in doubt as to whether the unit
is properly grounded.
• This generator is equipped with a grounding terminal for added
protection. Using the ground path from the generator to an external
ground source as instructed in the section labeled "Grounding
Instructions" in the Preparation section of this manual can be
necessary. Please consult a qualified electrician for local regulations.
• The generator is a potential source of electrical shock if not kept dry.
Keep the generator dry and do not use in rain or wet conditions. To
protect from moisture, operate it on a dry surface under an open,
canopy-like structure. Dry your hands if wet before touching the
generator.
• Plug appliances directly into the generator. Or, use a heavy duty,
outdoor-rated extension cord that is rated (in watts or amps) at least
equal to the sum of the connected appliance loads. Check that the
entire cord is free of cuts or tears and that the plug has all three
prongs,especially a grounding pin.
• NEVER try to power the house wiring by plugging the generator into
a wall outlet, a practice known as "back feeding". This is an extremely
dangerous practice that presents an electrocution risk to utility
workers and neighbors served by the same utility transformer. It also
bypasses some of the built-in household circuit protection devices.
• If you must connect the generator to the house wiring to power
appliances, have a qualified electrician install the appropriate
equipment in accordance with local electrical codes.
8
2 . DISCRIPTION
2 .1 Control panel
3. DESCRIPTION
3. CONTROL FUNCTION
3.1 Switch knob
Recoil
① Engine switch \fuel valve "OFF";
Ignition circuit is switched off. Fuel is switched off.
① Carrying handle
The engine will not run.
Fuel tank cap
② Engine switch \fuel valve \ choke "ON"
Control panel
Ignition circuit is switched on. Fuel is switched on. Choke is switched on.
Recoil starter
The engine can be running.
Oil filler cap
③ Engine switch \fuel valve \ choke "CHOKE" ;
Louver
Ignition circuit is switched on. Fuel is switched on. Choke is switched off.
Muffler
The engine can be start.
Spark plug maintenance cover
TIP: The choke is not required to start a warm engine.
3.1 LED Function Display (BE3600IE)
3.2 LED functions display(For electric start version)
5
6
1
2
3
4
1
Oil change indicator
5
Multi functional digital meter
2
Air cleaner maintenance indicator
6
Fuel level indicator
3
Spark plug maintenance indicator
On-load indicator
7
Switch button
Oil alert indicator
4
8
- 10 -
DESCRIPTION
Electric
;
7
8
- 8 -
11
9
10
9
Inverter running indicator
10
Inveter alert indicator
Power display
11
9