Page 1
INVERTER GENERATOR BE3500IP BE3600IE User Manual...
Page 2
TABLE OF CONTENTS TABLE OF CONTENTS Maintenance Safety Introduction 25 Maintenance Safety Warnings 27 Spark plug inspection Safety Information 28 Carburetor adjustment 28 Engine oil replacement Description 29 Air filter 9 Description 30 Muffler screen 11 Control Panel 31 Fuel tank filter Control Function 31 Fuel filter 12 3 in 1 switch knob...
Page 3
The safety alert symbol ( ) is used with a signal word (DANGER, be read thoroughly before initial use, and referred to often to make sure CAUTION, WARNING), a pictorial and/or a safety message to alert adequate safety and service concerns are being addressed.
Page 4
• NEVER operate the generator in an explosive atmosphere, near switches in the appliance.
Page 5
• This generator is equipped with a grounding terminal for added protection. Using the ground path from the generator to an external ground source as instructed in the section labeled “Grounding Instructions” in the Preparation section of this manual can be Recoil Electric necessary.
Page 6
DESCRIPTION DESCRIPTION 3.2 Control Panel 240V Recoil Voltage-U000, Frequency-F00.0, Total working time-000.0(0.1h) , Working hours at one time-00.00 Switch the display by pushing Oil change indicator, first time indicate after 50hrs, and then indicate once every 100hrs. Every indicating lasts 1hr. Air cleaner maintenance indicator, indicate once every 100hrs.
Page 7
“ON”; Ignition circuit is switched on. Fuel is switched on. Choke is switched When the overload indicator light comes on and power generation stops, off. The engine can be running after initial starting. proceed as follows: (3) Engine switch\fuel valve\choke “CHOKE”;...
Page 8
Ground (Earth) terminal (1) connects the earth line for prevention of elec- 4.6 Engine smart control (ESC) tric shock. All electrical tools and appliances operated from this generator, must be properly grounded by use of a third wire or be ① “Double Insulated”...
Page 9
5.2 Engine oil TIP: Pre-operation checks should be made each time the generator is NOTICE used. • Check oil levels before starting the engine. If empty, refill with sufficient engine oil.
Page 10
“ON”. Press the electric start switch as shown TIP: The generator can be used with the rated output load at standard atmospheric conditions. TIP: The choke is not required to start a warm engine. Push the choke in the figure.
Page 11
6.3 Alternating Current (AC) connection TIP: Turn off any electric devices. WARNING • Be sure any electric devices are turned off before plugging them in. 1. Turn the ESC to “OFF” (1). NOTICE • Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.
Page 12
• Be sure the ESC is turned off while charging the battery. of a generator. Otherwise, generator damage may occur. • Be sure to connect the red battery charger lead to the positive (+) battery terminal ,and connect the black lead to the negative (-) battery terminal.
Page 13
20hrs of months or 100hrs of • If the generator is to supply medical equipment, advice should first be operation every 50hrs operation of operation obtained from the manufacturer, a medical professional or hospital.
Page 14
TORCH F6RTC/F6TC Spark Plug Gap: 0.7-0.8mm Spark Plug Gap: 0.6-0.8mm(0.024-0.03in) TIP: The spark plug gap should be measured with a wire thickness gauge TIP: The spark plug gap should be measured with a wire thickness and, If necessary, adjusted to specification.
Page 15
1. Remove the screws ①, and then remove the cover ②. 1. Remove the screws ①, and then remove the cover ②. The carburetor is a vital part of the engine. Adjusting should be left to our 2. Remove the screw ③...
Page 16
6. Install the muffler screen and the muffler cap. 7. Install the cover and tighten the screws. 7. Install the cover and tighten the screws. The engine and muffler will be very hot after the engine has been run. 6.6 Fuel tank filter 6.6 Fuel tank filter The engine should never run without the foam element;...
Page 17
STORAGE TROUBLESHOOTING 8.2 Engine 8. STORAGE Perform the following steps to protect the cylinder, piston ring, etc. from Long term storage of your machine will require some preventive corrosion. procedures to guard against deterioration. 1. Remove the spark plug, pour about one tablespoon of SAE 10W-30 into the spark plug hole and reinstall the spark plug.
Page 18
9.2 Generator won’t produce power · Safety device (DC protector) to “OFF”…. Press the DC protector to “ON”. · The AC pilot light (Green) goes off …. Stop the engine, then restart. 10. SPECIFICATIONS 9. SPECIFICATIONS BE3500IP R3000is-2 BE3600IE R3000ie-2 Model No. Type...
Page 19
THE POWER YOU NEED. If you need assistance with the assembly or operation of your Generator please call 1-866-850-6662...