Installation Instructions
BMS Sensor Connection Kit and
Retrofit Connection Kit
Series 909, LF909, 909RPDA
2½" – 10"
Read this Manual BEFORE using this
equipment.
Failure to read and follow all safety and
use information can result in death,
serious personal injury, property damage,
or damage to the equipment.
Keep this Manual for future reference.
You are required to consult the local building and
plumbing codes prior to installation. If the information
in this manual is not consistent with local building or
plumbing codes, the local codes should be followed.
Inquire with governing authorities for additional
local requirements.
NOTICE
Use of the SentryPlus Alert
the need to comply with all required instructions, codes,
and regulations related to the installation, operation, and
maintenance of the backflow preventer to which it is
attached, including the need to provide proper drainage
in the event of a discharge.
Watts is not responsible for the failure of alerts due to
connectivity issues, power outages, or improper installation.
Monitor relief valve discharge with smart and connected
technology for flood protection. The BMS Sensor
Connection Kit activates the flood sensor to enable
functions that detect flood conditions. The BMS Sensor
Retrofit Connection Kit upgrades existing installations
by integrating and activating the flood sensor to enable
functions for flood detection. When excessive relief valve
discharge occurs, the flood sensor energizes a relay
signaling flood detection and triggers real-time notification
of potential flood conditions through the building
management system.
technology does not replace
®
IS-FS-909L-BMS
Connection Kit
Retrofit Connection Kit

Publicité

loading

Sommaire des Matières pour Watts 909 Serie

  • Page 1 Watts is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation. Retrofit Connection Kit Monitor relief valve discharge with smart and connected technology for flood protection.
  • Page 2 Kit Components components, activation module, ground wire, and power The upgrade kit includes the activation module, ground adapter (ordering code 88003051, sizes 21/2" to 3"; wire, and power adapter (ordering code 88003050). ordering code 88003054, sizes 4" to 10"). The retrofit kit includes the flood sensor and related A.
  • Page 3 Mounting the Activation Module The activation module receives a signal from the flood sensor when a discharge is detected. If the discharge meets the conditions of a qualifying event, the normally open contact is closed to provide a signal to the BMS input terminal. 1.
  • Page 4 ADAPTER SHOWN Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
  • Page 5 Watts n’est pas responsable de la défaillance des alertes Trousse de connexion de modernisation due à des problèmes de connectivité, à des coupures de courant ou à...
  • Page 6 Composants de la trousse d’inondation et les composants connexes, le module La trousse de mise à niveau comprend le module d’activation, le fil de mise à la terre et l’adaptateur d’activation, le fil de mise à la terre et l’adaptateur d’alimentation (code de commande 88003051, tailles d’alimentation (code de commande 88003050).
  • Page 7 Montage du module d’activation Le module d’activation reçoit un signal du capteur d’inondation lorsqu’une évacuation est détectée. Si l’évacuation répond aux conditions d’un événement admissible, le contact normalement ouvert est fermé pour fournir un signal à la borne d’entrée BMS. 1.
  • Page 8 OPTION ILLUSTRÉ Garantie limitée : Watts Regulator Co. (la « Société ») garantit que chaque produit est exempt de tout défaut de matériau et de fabrication dans le cadre d’une utilisation normale pendant une période d’un an à compter de la date d’expédition initiale. En cas de défaut pendant la période de garantie, la Société...
  • Page 9 Watts no es responsable de la falla de las alertas debido a problemas de conectividad, cortes de energía o Kit de conexión de retroadaptación instalación incorrecta.
  • Page 10 Componentes del kit el módulo de activación, el cable a tierra y el adaptador El kit de actualización incluye el módulo de activación, de alimentación (código de pedido 88003051, tamaños el cable a tierra y el adaptador de alimentación (código 21/2"...
  • Page 11 Montaje del módulo de activación El módulo de activación recibe una señal del sensor de inundación al detectar una descarga. Si la descarga cumple las condiciones de un evento calificado, el contacto normalmente abierto se cierra para proporcionar una señal a la terminal de entrada del BMS. 1.
  • Page 12 MOSTRADO Garantía limitada: Watts Regulator Co. (la “Compañía”) garantiza que cada producto está libre de defectos en el material y la mano de obra cuando se usa de forma normal en un período de un año a partir de la fecha de envío original. En caso de que tales defectos se presenten dentro del periodo de garantía, la Empresa, a su criterio, reemplazará...

Ce manuel est également adapté pour:

Lf909 serie909rpda serie