AEMC Instruments PEL 102 Notice De Fonctionnement page 4

Adaptateur secteur pour pel, à utiliser uniquement sur 600 v cat iii installation pollution 2

Publicité

Adapter - 600 V CAT III Power to Phase Adapter for use with
Models PEL102 and PEL103 ......................................................................................Cat. #2137.90
Accessories and Replacement Parts
Set of 12 Color-coded Input ID Markers .....................................................................Cat. #2140.45
The power adapter is used to supply the device when it is used for an extended period. The internal
battery of the PEL remains charged, enabling the device to continue to operate in the event of a power
outage up to 30 minutes.
■ Connect the adapter to the voltage inputs of the PEL.
■ Connect the C7 plug from the adapter to the
■ Connect the voltage inputs to the adapter, following the markings on the adapter. Connect the current
inputs directly to the PEL, per normal operation (see the illustration on page 5).
The L1 and N or L1 and L2 voltage inputs must be connected for the adapter to operate.
The adapter can operate on (50 and 60) Hz networks.
Electrical
Range of use
Max. input voltage
Max. output voltage
Frequency
Consumption
Environmental
Operation: (32 to 122) °F (0 to 50) °C and (10 to 85) % RH
Storage: (-4 to 158) °F (-20 to +70) °C and (0 to 95) % RH
Indoor use: Level of pollution: 2; IEC 61010-1 600 V CAT III
Altitude: < 6562 ft (< 2000 m); Storage: < 32,808 ft (< 10,000 m)
Mechanical
Dimensions (L x H x D): (5 x 3.8 x 1.5) in (127 x 97 x 39) mm
Weight: 7 oz (200 g) approximately
Cord: 11 in (30 cm) approximately
Ingress protection:
Drop Test:
Electromagnetic compatibility
IEC 61326-1 or BS IEC/EN 61326-1
Safety:
600 V CAT III IEC/EN 61010-2-30 or BS EN 61010-2-030
Specifications are subject to change without notice.
This instrument contains no parts that can be replaced by personnel who have not been specially trained
and accredited. Any unauthorized repair or replacement of a part by an equivalent may impair the safety rating.
Cleaning: Disconnect all inputs to the device and remove from the PEL. Clean with a soft cloth
moistened with soapy water. Wipe dry completely.
Repair: For all repairs, please contact the AEMC
4
ORDERING INFORMATION
WARNING: Use Only on CAT III Pollution 2 Location
SPECIFICATIONS
Phase-to-neutral voltage: (100 to 346) V
Phase-to-phase voltage: (100 to 600) V
Permanent: 660 V
360 V peak
(50 and 60) Hz
100 VA max at (50 and 60) Hz
IP 40 per IEC 60529 except for terminals (IP20)
IK 04 per IEC 50102
3.3 ft (1 m) per IEC/EC 6101-2-030 or BS EN 61010-2-030
: Emissions and immunity in an industrial setting compliant with
MAINTENANCE
USE
input of the PEL.
AC
Instruments or your local distributor.
®
PEL Power Adapter - User Manual
AC
AC

Publicité

loading

Ce manuel est également adapté pour:

Pel 103Measure up 2137.90