CR 5017
MAINTENANCE
Before undertaking any maintenance operation, disconnect the appliance from the power supply.
-
This appliance does not require any particular maintenance. For cleaning it is recommended to use a
-
soft moist rag and neutral detergent. Do not use an abrasive cloth or devices which could affect the
outward appearance of the appliance. Check that the parts exposed to the heat rays and the ventilation
are free of dust and dirt.
During cleaning, be careful not to touch the quartz heating elements.
In case of breakdown and/or poor function of the appliance, disconnect the appliance from the power
-
supply and contact an authorized service center. Always request the use of original spare p arts.
The non-observation of these instructions can compromise the safety of the appliance and render
guaranty invalid.
TECHNICAL CHARACTERISTICS
Model: CR 5017
Voltage: 230 V
Power: 1500 W
Tension: 50 Hz.
Item
Symbol
Heat output
Nominal heat
P
nom
output
Minimum heat
P
min
output
(indicative)
Maximum
P
max
continuous
heat output
Auxiliary electricity consumption
At nominal
el
max
heat output
At minimum
el
min
heat output
In standby
el
SB
mode
Value
Unit
1.5
KW
0.75
KW
1.5
KW
c
,
N/A
KW
N/A
KW
0
W
Item
Type of heat input, for electric storage local space heaters
only (select one)
manual heat charge control, with integrated thermostat
manual heat charge control with room and/or outdoor
temperature feedback
electronic heat charge control with room and/or
outdoor temperature feedback
fan assisted heat output
Type of heat output/room temperature control (select one)
single stage heat output and no room temperature
control
Two or more manual stages, no room temperature
control
with mechanic thermostat room temperature control
with electronic room temperature control
electronic room temperature control plus day timer
electronic room temperature control plus week timer
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
Unit
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
14