Installation
Installation check codes
Check code
0
Vent condition is good.
Clg (Cg)
The vent is clogged.
About 80 % of the vent is clogged.
C80 (C8)
(This may decrease the drying
performance.)
Over 90 % of the vent is clogged.
C90 (C9)
(This may lead to poor drying performance
or cause malfunction)
The internal temperature of the dryer is
too low (below 32 °F (0 °C)) or too high
Ct
(over 104 °F (40 °C)) and therefore vent
blockage cannot be detected.
tC
Temperature sensor error
Unit is detecting items inside the drum or
C1
there is an error on the dry sensor.
dC
Unit is detecting door is open
9C1
Abnormal voltage detected
Detection of abnormal temperature in
HC
drum.
34
English
Untitled-1 34
Meaning
Solution
1. Clean the lint filter.
2. Check your vent condition. (Refer to the
"Ducting requirements" section)
* You must take measures (such as
cleaning) through expert personnel.
Leave the dryer at room temperature
(41~95 °F (5~35 °C)) for an hour and check
again.
Contact a service center.
Remove items from the drum and check
again.
If the problem continues, contact a service
center.
Close the door properly and check again.
If the problem continues, contact a service
center.
Check the power connection. (Refer to the
"Connect the electrical wiring (for electric
models)" section)
If the problem continues, contact a service
center.
Check the power connection.
Check the vent condition if the problem
continue, contact a service center.