Technical Data
Input
Nominal voltage:
115/230 VAC universal
as required to meet EN61000-3-2
Power factor (PFC):
Output
SDP5-5
SDP2-12
Nominal Voltage
5 V
12 V
Power Back Immunity
> 10 V
> 22 V
Overvoltage Protection
< 6.7 V
<18 V
Adjustable Range
5-6 V
10-12 V
Ripple
<50 mVpp
< +2% overall
Tolerance
<0.5%
Line/Load Regulation
Standards, Certifications
EMC
Emissions
EN 61000-6-3, Class B EN55011, EN55022 Radiated
Conducted including Annex A
Immunity
EN 61000-6-2, EN61000-4-2 Level 4, EN61000-4-3 Level 3,
EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3
output. EN61000-4-5 Isolation class 4, EN61000-4-11,
Transient protection according to VDE 0160/W2 over entire load
range.
Approvals
EN60950, UL508 Listed, cULus, UL 60950, cURus, CE (LVD
73/23 & 93/68/EEC), (EMC 89/336 & 93/68/EEC). EN61000-3-2,
EN60079-15 (Class 1, Division 2 hazardous location, Groups A,
B, C, D w/ T3 temp class up to 60˚C Ambient.) UL60950 testing
to include approval as NEC Class 2 power supply acc. To NFPA
70 art. 725-41 (a)(2).
Environmental Data
Ambient temperature
Storage/Shipment
-25˚C...+85˚C
Full nominal load
-10˚C...+60˚C
Derated
+60˚C...+70˚C
Degree of protection
IP20 (EN60529), Protect the unit from moisture (and
condensation)
Installation
Fusing
Input
Internally fused.
Output
Outputs are capable of providing high currents for short periods
of time for inductive load startup or switching.
Mounting
Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Unit
should handle normal shock and vibration of industrial use and
transportation without falling off the rail.
Connections
Input/Output: screw terminals, connector size range: 20-12AWG
(0.5-2.5mm2) for solid conductors.
This equipment is suitable for use in Class 1, Division 2, Groups A,B,C,D or non-
hazardous locations only
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability
for Class 1, Division 2.
WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has
been switched off or the area is known to be non-hazardous.
SDP3-15
SDP1-48
15 V
48 V
> 22 V
> 63 V
< 20 V
< 60V
12-15 V
48-56 V
DIN Rail Mounting
Snap on the DIN Rail:
1. Tilt unit as
illustrated
2. Put it onto the DIN
Rail
3. Push downwards
until stopped
4. Push at the lower
front edge to lock
5.
Shake the unit
slightly to ensure
that the unit is
secure
SDP Series
Power Supplies
SDP5-5-100T
SDP2-12-100T
SDP3-15-100T
SDP1-48-100T
Rev. 08/13/03
Montaje en Riel DIN
Monture du Rail DIN
Atorar en en Riel DIN:
Poser le Rail DIN:
1. Incline la unidad
1. Faire pivoter
como se ilustra
l'appareil comme
illustré
2. Póngala sobre el Riel
DIN
2. Poser sur le Rain
DIN
3. Empuje hacia abajo
hasta que se
3. Enfoncer jusqu'à
detenga
arrêt
4. Empuje de la parte
4. Appuyer sur le bord
baja del frente para
inférieur pour fixer
asegurar
5.
Vérifier que l'appareil
5.
Mueva la unidad
est bien fixé
ligeramente para
verificar está segura
Technical Services
USA
(800) 377-4384
International
(847) 679-7800
www.solaheviduty.com

Publicité

loading

Sommaire des Matières pour Sola Hevi Duty SDP5-5-100T

  • Page 1 (0.5-2.5mm2) for solid conductors. This equipment is suitable for use in Class 1, Division 2, Groups A,B,C,D or non- Technical Services hazardous locations only SDP5-5-100T SDP2-12-100T (800) 377-4384 WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class 1, Division 2.
  • Page 2 Se adapta de manera sencilla en sistema Riel DIN TS35/7.5 ó dérailler. Sistema TS35/15. La unidad debe soportar un golpe normal y SDP5-5-100T vibración de uso industrial y transportación sin caer del riel. Connexions Entrée/Sortie: terminals des vis, dimensions du raccordement: 20-12AWG (0.5-2.5mm2) pour des...

Ce manuel est également adapté pour:

Sdp serieSdp2-12-100tSdp3-15-100tSdp1-48-100t