Error reports
In case of any fault, please handle it according to the prompt code on the disply screen.
Fault prompt on the display screen:
When using this product, if the following code appears on the screen, repair or handle
it according to the corresponding fault prompt.
Alarm content
No error
Current sensor error
MOSFET failure
Hall blade sensor failure
Overcurrent protection
Opening blocked / rotor blocked
Phase error
Overcurrent / Undercurrent
Overheating MOS/chip
Communication error
Bit error
EEPROM error
Phase detection failure
Programming error
Scheduled maintenance
Battery error
Communication error between
board and batteries
Meanings of shears alarms
The board LED
The buzzer of the card
ashes several times
sounds several times
0
2
3
4
5
6
7
8
9
10
10
11
12
13
15
16
17
19
Error code indicated
on the display
0
E00
6
E02
6
E03
3
E04
5
E05
3
E06
4
E07
1
E08
6
E09
2
E10
7
E10
6
E11
4
E12
6
E13
5
E15
9
E16
10
E17
More