ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate situated
inside the hood. If provided with a plug connect the hood to a socket in compliance with
current regulations and positioned in an accessible area, after installation. If it not fitted
with a plug (direct mains connection) or if the plug is not located in an accessible area,
after installation, apply a double pole switch in accordance with standards which
assures the complete disconnection of the mains under conditions relating to over-
current category III, in accordance with installation instructions.
WARNING! Before re-connecting the hood circuit to the mains supply and checking
the efficient function, always check that the mains cable is correctly assembled.
If the cable is not fitted with a plug, connect the wires according to the following table:
Mains voltage and frequency
Refer to the rating indicated on the plate inside of the hood
Replacing the power cable
The hood is provided with a special power cable ; if the cable is damaged, request a
new one from Technical Service.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a
drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensable length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
The company declines any responsibility whenever these regulations are not respected.
FILTERING OR DUCTING ?
!
Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY KIT must be installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished or must be bought separately.
Note: If furnished, in certain cases, the additional activated carbon filtering system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering version is present in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on
top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
Wire connection
: yellow/green
N : blue
L : brown
20