Télécharger Imprimer la page

Urmet sinthesi steel 1158/45 Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

also set the second digit. At this point, the display
will show:
where 'XY' is the new door release time set.
After 3 seconds, the display will return to normal
functioning.
ADVANCED PROGRAMMING
FUNCTIONS
A number of particular functions, not generally
used, are described below.
DELETION OF AVAILABLE KEYS
To delete an available user key from the memory,
you can use a simpler procedure than that described
above for lost keys:
− using a MASTER key, access the deletion menu
with the following shown on the display:
− present the key to be deleted.
− if the key presented is effectively present in the
memory, the buzzer will emit three beeps and the
display will show the 'key number' for approx. 7
seconds.
− when the key number is shown on the display,
present the MASTER key to confirm deletion.
To restore normal functioning, present a MASTER
key to the front panel.
ACCESS IN THE CASE OF LOSS OF
MASTER KEY/STORAGE OF NEW
MASTER KEYS
It is always possible to access a device, even
without the MASTER keys, provided you have a
blank key, i.e. a key that has never been stored as
user key on that device.
Proceed as follows:
− open the frame, so as to access the rear red
button.
− press the rear red button briefly;
− wait until the following is displayed:
− press the rear red button again briefly;
− present the blank key which will be stored as
MASTER key in addition to or in replacement of
(if 3 have already been stored) of the MASTER
DS1148-001
'tXY'
keys present.
− present this new MASTER key for at least 7
seconds so as to restore normal functioning.
− use this new MASTER key to access the device.
ACCESS PASSWORD
Access from the rear red button can be protected
using a 3-digit password.
When a password is entered in the device, the rear
red button can be accessed subsequently only re-
entering the password.
WARNING:
If all the MASTER keys of a device equipped
with password are lost and you have forgotten
the password, IT IS IMPOSSIBLE TO ACCESS
DEVICE PROGRAMMING. In this case, get in
touch with the URMET technical assistance
service directly which will eliminate the password
without deleting any of the user keys.
The password can be set on any device without
password (therefore on any device that leaves the
factory).
Once the password has been entered, it cannot be
modified.
It can be deleted only using the complete memory
reset procedure (see below): IT IS ADVISABLE
THEREFORE
TO
BEFORE STARTING TO STORE THE USER KEYS
SO THAT THIS CAN BE DELETED IN THE CASE
OF ERRORS DURING THE ENTRY PHASE.
Proceed as follows:
− press the rear red key briefly;
− wait until the following is displayed:
− press the rear red key and hold it down. The
following is displayed:
and the '0' digit increases by one unit,
approximately once a second, cyclically (i.e.
moving from 9 to 0).
Release the key when the digit you want to set is
displayed.
Press and release the rear red key again twice
so as to set the other two digits. Now the display
will show the configured password. Press the
rear red key briefly to confirm the password.
In this way, you will access the MASTER key
programming menu from which you can exit using
a MASTER key as described in the 'Installation
and Configuration' paragraph.
ENTER
THE
PASSWORD
11

Publicité

loading

Ce manuel est également adapté pour:

Sinthesi 1148/45