This program allows you to charge or discharge your Lead Acid batteries.
This function allows to charge lead Acid batteries from 2 up to 20 Volts. Please input the charge current and
nominal voltage of the battery connected. Please note that Lead Acid batteries should be charged slowly, with 0.1C
Charge
charge current ( 1/10 of their total capacity). It is necessary, in most time, to disable the safety timer to avoid partial
charge.
Same as above function, for discharging the battery.
Discharge
Your charger is featuring a user memory handling up to 5 customised programs. You can save or recall these programs at any time by getting in
this menu.
To save a program, select a memory slot between 1 and 5, then validate.
Choose the battery type, the voltage if necessary, and the maximum charge capacity.
Save
Press « Enter » during 3 seconds, a « * »symbol should blink in top right of the screen.
Press Enter and select the charge current, and validate again.
For Lithium batteries, please check the number of cells and validate.
Then, press again "Enter" for 3 seconds, the message "Save" will appear for a few instants, the program is now
saved in the charger memory.
This function allows you to load a previously saved program. Choose the program number you wish to load, and
press « Enter » for 3 seconds. You will then arrive to the battery charge / discharge program you had recorded in
Load
this program.
« Pb Battery » progam
« Program Select » Menu detail