Detailing « User Set Program »
This screen allows you to choose the kind of Lithium batteries. 3 main Lithium batteries famillies exist and are
related to Rc model application : Li-Po / Li-Ion / Li-Fe. These batteries have different voltage and charging
processes. Please note that only compatible rechargeable Lithium batteries can be connected to the charger.
This screen shows you the minimum power supply voltage the charger will accept before cutting off any process.
You can set a value between 10 and 11 Volts.
You can choose here to enable or disable the key bips and charger indications bips. We recommend you to keep on
the charger Buzzer beep to be informed of any state change during a process
This screen allows you to setup a maximum capacity (mAh) which the charger will not go over, in any case. This is
a supplementary security very usefull for slow charge of Lead Batteries.
You can enable or disable the security timer, and set up a maximum charge / discharge time.
Some batteries can heat up during charge / discharge cycles. You can input here a value, in minutes, of waiting time
to let the battery cool down between two process, like the charge / discharge one.
This is the temperature sensor cut off value to set up in this screen. If the temperature sensor is not connected, or
defective, this function is disabled.
You can choose here the delta Peak sensivity for charge end detection Ni-Cd batteries). The value must be choosen
between 5 and 20 mV. If you are not sure about the value to enter, please use the " default" setting.
Same as above, but for Nni-Mh batteries. Standard value is around 7mV, but we recommend you to make some
tests and to use the temperature sensor with a protection set at 55° Celsius to start if you want to increase the delta-
Peak value.
This screen indicates the time allowed to the Lithium batteries cells detection. In most cases, a few seconds are
necessary to detect the correct number of cells, but in some cases it can be longer. We recommend you to leave the
value at 10mn, and to always check the battery cells number before validating the charger detected values, and to
change them if necessary to match the connected battery pack.