CDVI PROFIL100EINT Manuel D'installation page 5

Clavier codé rétro-éclairé avec électronique intégrée
Masquer les pouces Voir aussi pour PROFIL100EINT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
PROFIL100EINT
Illuminated Mullion Weatherproof Keypad Self Contained
Default values
- Without codes,
- Illumination time: 10 seconds,
- Relay release time: 1 second,
- Code length: 5-digits,
- Master Code: 1 2 3 4 5,
- Programming security time :
120 secondes,
- Code length for sub master code:
Version 1 relay (Group 1) = A and B,
Version 2 relays (Group 2) = 1 and 3.
Audible signal:
The buzzer indicates different audible
signals. It can be turned off
by cutting the ST1 wire
on the remote controller
- 1 short beep: Keypad powered,
- 1 long beep: Data computing
in programming or access granted,
A. RESET MASTER CODE
AND USER CODES
1. Enter the master code twice
(1 2 3 4 5 default value master code).
- The red LED lights on,
- 2 beeps are emitted to confi rm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
- The green LED lights on during 1 second,
- One beep is emitted,
- Press on A and B to confi rm reset
of all memory of the keypad,
- The green LED lights on,
- Wait until the LED lights off,
- Wait for two beeps,
- The master code is restored
to its default value 1 2 3 4 5
and all the User codes are deleted
from the keypad,
- The keypad is reset, the red LEDs remain
on and then turn off.
- Once the reset is completed
then the keypad returns to a stand-by
operating mode,
OR
1. Cut the power. Place the jumper on P2.
2. Put the power back.
- The green LED lights on,
- Wait approximately 3 seconds, one beep
is emitted,
- 2 short beeps: Enter or Exit from
programming,
- 4 short beeps:
Data computing error.
Code length
- The master code and the User
codes can be of 4 or 5-digits
in length.
- All the keypad keys can be
used to program a code.
- The master code and the Pin
code can be of 4, 5 or 6-digits code.
- The master code CAN NOT
be used as a PIN code
(User Pin code).
- To delete a specifi c User
pin Code replace it by 0 0 0 0
if code length is 4-digits format
or replace it by 0 0 0 0 0
if the code is in 5-digits format.
B. SETTING CODE LENGTH
Control by exit push button
- The connection of push button P1
is intended to control relay 1
(the mode and the timer
are programmable).
- The clock switch H1 allows
the "Key" key to be used
as an outdoor button.
- If the clock switch is open,
the "Key" key is inactive.
- If the clock switch is closed,
the "Key" key is used
for free unlocking.
Consumption
(With the 2 relays controlled
and permanent lighting)
- At 12V dc : max. 90mA,
- At 12V ac : max. 70mA,
- At 24V dc : max. 50mA,
- At 24V ac : max. 40mA.
- The green LED lights off,
- Remove P2 jumper.
3. The master code is restored
to its default value 1 2 3 4 5
All the User codes are deleted from the keypad.
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
- The red LED lights on,
- 2 beeps are emitted to confi rm
entry in programming mode.
2. Press A4 to program the code length.
- The green LED lights on during 1 second,
- One beep is emitted,
- Press 4, 5 OR 6 for the digit code,
- The green LED lights on during 1 second,
- Two beeps are emitted to confi rm
programming of the code length.
3. Press A5 to modify the master code.
- The green LED lights on during 1 second,
- One beep is emitted,
- Enter the new 4, 5 or 6-digits master code,
- The green LED lights on during 1 second,
- One beep is emitted to confi rm
programming of the new master code.
4. Press B to exit from
programming mode.
2 beeps are emitted to confi rm that the key-
pad is in stand-by operating mode.
4 beeps indicate a data computing error.
cdvi.com