NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED
Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Not For Indoor Use.
Indoor use permitted only for the temporary
heating of buildings under construction,
alteration or repair.
DANGER
LEAD TO DEATH!
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm)
for each 100,00 Btu / Hr. of heater output. Provide
a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
150T-SDR
5.3 ft.²
3760 cm²
Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 6 feet long and is a minimum of 14
AWG rating.
4. Press the power button to power on the
heater.
5. Select desired temperature using temperature
buttons.
6. The heater will ignite once the temperature
setting is higher than the ambient
temperature in the space.
© 2016, Pinnacle Climate Technologies, Inc.
All manuals and user guides at all-guides.com
TO A POWER SOURCE
Operation
CARBON
MONOXIDE
POISONING MAY
220T-SDR
6.5 ft.²
5990 cm²
TIP: If the heater does not ignite, the
thermostat may be set too low. Increase
the temperature to a higher setting until the
heater ignites.
TIP: If the heater does not ignite; press
power button to power off the heater,
check steps 1-3 above and press power
button to power ON the heater.
Stopping / Restarting Heater:
-
To stop the heater, move the power switch to
the "Off" position and unplug the power cord.
-
To restart the heater; wait 10 seconds and
follow ignition steps.
°F
Figure 3
SilentDrive® Forced Air Heater User's Manual