Télécharger Imprimer la page

Rointe CT.2 Mode D'emploi page 3

Publicité

Les langues disponibles

Les langues disponibles

CT.2 Wi-Fi Thermostat
This thermostat is designed to improve the thermal comfort of your home by providing
programming of your underfloor heating system. It is designed to receive temperature signals
through the following sensors:
1. Air sensor located inside the thermostat.
2. Sensor installed on the floor (see underfloor heating instructions for more details).
This thermostat is not a safety device and should only be used with Rointe heating products.
To avoid damaging the floor, you must select the correct floor type during the thermostat
WARNING - important safety note.
programming process.
This product uses mains voltage and its installation must be carried out by a qualified electrician.
You should always disconnect the power supply before attempting to install or repair the thermostat.
It should not be switched on unless you are sure that the entire heating installation complies with the
current general requirements for electrical installations. The electrical installation must comply with
the latest wiring regulations.
This thermostat must be installed inside an electric wall box that has a depth of at least
35mm. For optimum performance, this thermostat should be located in an area with good
ventilation. It should not be positioned next to a window or door, in direct sunlight or near a heat
source (e.g. a radiator or TV). This thermostat is designed to operate between 0ºC and 55ºC,
with a relative humidity below 80%.
1. Separate the front cover of the thermostat from the wall module.
2. Place the front cover in a safe place to avoid damage.
3. Pass all the cables to the wall box. Make sure you have included the following:
- Feed (phase and neutral).
- Heating element (phase and neutral or only phase of the switch).
- Floor sensor or air sensor.
4. Pass the wires through the wall box and complete the wiring.
IMPORTANT: Make sure the cables are fully inserted into the terminals and
tightened securely. All loose wires should be cut as they could cause a short circuit.
If more heating elements are connected, an electrical bypass box will be required.
Note: Always make sure that the sensor cable is installed in a conduit separate from the
power supply of the thermostat and the heating system.
1. Release the front cover.
2. Remove the back plate.
3. Screw the back plate to the wall box with a screwdriver.
4. After connecting the cables (see connection diagram), mount the thermostat to the back
plate and replace the housing and frame.
NTC
- Supply voltage: 230V +/- 10% at 50Hz
- This thermostat is not designed to be used with an intermittent power supply.
- Maximum load: 16A resistance or 3,680W
- Insulation class: II
- IP21
- Wi-Fi connectivity
- Floor sensor: 10 KOhm
NETWORK
SYNCHRONIZATION / BACK
After completing the initial configuration, the thermostat will display the setpoint
temperature and the temperature read by the sensor.
The initial configuration starts when the thermostat is switched on for the first time.
7.1. CONFIGURATION
01. Time and date
02. Select sensor
03. Wi-Fi synchronization
1
Download the Rointe Connect app and register.
2
The Wi-Fi network symbol will blink. Press the icon for 3 seconds.
The thermostat will generate a Wi-Fi network (SSID) and show the last 3
3
digits of this network on the screen.
Ensure your smartphone is connected to the same Wi-Fi network you
4
want the thermostat connected to.
Connect your smartphone to thermostat Wi-Fi network (e.g. ROH_0731).
5
"PrO" characters will flash and thermostat will restart.
ON - OFF / OK
VALUE SHOWS BLINKING WHILE YOU ARE CONSUMING

Publicité

loading