FLUSH Tile Flange Installation – FLUSH (shown): To adjust Flange height turn four Jack Screws clockwise until Cover is
flush to surface of tile floor. Minimum tile thickness 3/16" [4.8 mm].
Figure F
Ceramic Tile
Box
Furniture
Floor Box
Divider
depth
Feed Cover
CFB2G25, xxCR CFB2FFDIV 2-1/2" 2GTFFCVRxx
CFB2G30, xxCR CFB2FFDIV
3.0"
2GTFFCVRxx
See Figure C for installation of CFB2FFDIV dividers.
Figure 4
Remove tabs at score lines on divider for CFB2Gxx series boxes.
FLUSH Flange Installation – FLUSH (shown): To adjust Flange height turn four Jack Screws clockwise until Cover flush to
surface of floor.
Figure G
Vinyl Composition Tile
Box
Furniture
Floor Box
Divider
depth
Feed Cover
CFB2G25, xxCR CFB2FFDIV
3.0"
2GTFFCVRxx
CFB2G30, xxCR CFB2FFDIV 3-1/2" 2GTFFCVRxx
See Figures 4 and C for installation of CFB2FFDIV dividers.
ATTACHING THE COVER: 2GTFFCVRxx rectangular Furniture Feed cover assembly shown.
• NOTICE: Use only electrical grade type RTV silicone sealant
to insure scrub water tightness.
• Attach Flush Flange with gasket to box using four Jack
screws.
• Attach cover assembly to top mounting plate using jack
screws. Fasten until flange is level and secure to floor.
• To adjust cover assembly turn jack screws counter clockwise
to raise or clockwise to lower. Sequentially turn four jack
screws as needed for proper leveling of flange to floor. The
jack screws have a 1 inch maximum adjustment.
• Apply bead of Silicone compound to top of each reducing
bushing, ¾" closure plug and 2" closure plug.
• Screw in ¾" closure plug into reducing bushing and tighten
until flush. Screw in reducing bushing to Cover and tighten
until flush with top of cover.
• Attach Cover with four #6-32 screws. Torque screws to 12-15
in-lbs of torque.[1.7N•m].(DO NOT
OVERTIGHTEN)
(Page 4)
04/14
PRINTED IN USA
PD2528
Apply Grout or
To attach Flush
Silicone
Flange, See Fig. 5.
Compound to
Ceramic Tile
Joint.
Concrete
To attach
Apply Grout or
Flush Flange,
Finished
VCT
Silicone
See Fig. 5.
Compound to
Concrete
Floor
Joint.
Figure 5
Apply silicone
all around top
lip of plug.
2" Closure Plug
Jack Screws
2 GANG AFB, CFB FURNITURE FEED COVER AND ACCESSORIES
Cover
Shown
Catalog no.'s 2GAFBFFCVRxx, 2GCFFCVRxx, 2GTFFCVRxx
Installed
after flange
CAUTION: RISK OF ELECTRIC SHOCK. Disconnect power before installing or servicing.
adjustment
is made.
NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, communication
(See Fig. 5)
standards, the following instructions, and any instruction included with individual devices.
NOTICE: Ensure data/communications circuits are separated from lighting/power circuits in accordance NEC® and
CE code requirements.
Jack
Use with 2GAFBFFCVRxx, 2GCFFCVRxx, and 2GTFFCVRxx series furniture feed rectangular covers with
Screws
dividers when used with AFB2G25, AFB2G25CHI, AFB2G55, AFB2G55CHI, CFB2G25, and CFB2G30 series
boxes. See Table 1, Table 2, and Figures.
Use with CFB2FFDIV furniture feed dividers when used with AFB2G25, AFB2G25CHI , CFB2G25 and CFB2G30
series boxes. See Table 1 and Figures.
Use with AFB2FFDIV and CFB2FFDIV furniture feed dividers when used with AFB2G55 and AFB2G55CHI series
Cover
Shown
boxes. See Table 2 , Figure D and Figure E.
Installed
after flange
CAUTION: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING.
adjustment
is made.
See Figure 4 for Cover installation.
(See Fig. 5)
Figure 1
Raised
Flange
Catalog No.'s
2GAFBFFCVRxx (AFB)
Jack
2GCFFCVRxx (FLAT)
Screw
2GTFFCVRxx (FLUSH)
3/4" closure plug
Reducing
bushing 1"-3/4"
Figure 2
Cover
Screw #6-32
Catalog No.
CFB2FFDIV
Flush Flange
Wiring Device-Kellems
Hubbell Incorporated (Delaware)
40 Waterview Drive
Shelton, Connecticut 06484
1-800-288-6000
Installation Instructions
AFB
FLAT
FLUSH
Figure 3
Catalog No.
AFB2FFDIV
PD2528
(Page 1)
PRINTED IN USA
04/14
English
®

Publicité

loading

Sommaire des Matières pour Hubbell 2GAFBFFCVR Serie

  • Page 1 • Attach Cover with four #6-32 screws. Torque screws to 12-15 in-lbs of torque.[1.7N•m].(DO NOT OVERTIGHTEN) ® Flush Flange Wiring Device-Kellems PD2528 (Page 1) PRINTED IN USA 04/14 Jack Screws Hubbell Incorporated (Delaware) 40 Waterview Drive Shelton, Connecticut 06484 1-800-288-6000 (Page 4) 04/14 PRINTED IN USA PD2528...
  • Page 2 Carpet Installation shown Carpet Installation shown See Fig. A - Cut opening in carpet as shown. See Fig. A - Cut opening in carpet as shown. See Fig. B, Fig. C - For installation of Furniture Feed dividers with 2 gang shallow box. See Fig.
  • Page 3 Wiring Device-Kellems Rebord PD2528 (Page 1) PRINTED IN USA 04/14 Hubbell Incorporated (Delaware) ras ce dernier. Vis de nivellement affleurant • Fixer le couvercle avec les 4 vis nº 6-32. Serrer les vis à un 40 Waterview Drive Shelton, Connecticut 06484 couple de 1,7 N•m.(NE PAS SERRER DÉMESURÉMENT...
  • Page 4 Montage sur moquette Montage sur moquette Consulter la Fig. A - Couper une ouverture dans la moquette selon l’illustration. Consulter la Fig. A - Couper une ouverture dans la moquette selon l’illustration. Consulter les Fig. B et Fig. C - Pour montage de cloisons dans une boîte double peu profonde destinée à alimenter le mobilier. Consulter les Fig.
  • Page 5 (Page 1) PRINTED IN USA 04/14 • Fijar la tapa con los 4 tornillos #6-32. Ajustar los tornillos con Tornillos niveladores Hubbell Incorporated (Delaware) a ras un par de 1,7 N•m. (NO SOBREAJUSTAR. 40 Waterview Drive Shelton, Connecticut 06484 1-800-288-6000...
  • Page 6 Figura C HUBBELL DE MÉXICO garantiza este producto, de estar libre de defectos en materiales y mano de obra por un año a partir de su compra. Hubbell reparará o reemplazará el artículo a su juicio en un plazo de 60 días. Esta garantía no cubre desgastes por uso normal o daños ocasionados por accidente, mal uso, abuso o negligencia.

Ce manuel est également adapté pour:

2gcffcvr serie2gtffcvr serie2gafbffcvrbrz