Télécharger Imprimer la page

Fairland DH-60 Notice D'installation Et Conseils D'utilisation page 25

Publicité

Les langues disponibles

Les langues disponibles

Parameter
code
1
C1
2
C2
3
C3
4
C4
5
C5
6
C6
7
C7
8
C8
9
C9
10
CA
11
Cb
12
CC
To modify the value of the parameter displayed, press the SET key. The value of the parameter will begin
to flash, use the arrow keys ( and ) to modify the parameter. Press the SET key to validate the modi-
fication.
Press
or
.
Installation of the heating element (option)
The heating element should only be installed by a qualified professional.
Stop the machine and cut the power supply to the dehumidifier.
1.
Remove the plastic casing: extract the 2 Phillips head screws located
midway up each side, and the 3 Phillips head screws on the bottom of
the machine on each side. Also, to facilitate removal, take the metallic
strip off the back of the machine. Free the casing by pulling it forward.
2.
Place the element flat over the fins and
tube condenser with the black grating
facing upwards and the connections
oriented towards the electrical box. Feed
the electrical wires through the opening
located on the right hand side.
Align the holes in the heating element plate
Parameter title
With or without heating
Heating element temperature
Humidity compensation to calibrate
the humidity sensor
Minimum time lapse between two
defrosting cycles
Defrosting cycle start temperature
Defrosting cycle end temperature
Maximum duration of the defrosting
cycle
Fan operation once the set point is
reached
Exhaust air temperature
Refrigerant temperature at the
evaporator inlet
EXV step no.
Overheating target value
with those of the base and insert the 4
screws to attach the heating element
to the machine.
3.
Open the lid of the electrical box
Allowed values
0 without / 1 with
From -20°C to +99°C
From -5% to +5%
From 15Min to 90Min
From -10°C to 10°C
From 0°C to 15°C
From 2Min to 12Min
0 the fan stops at the set point
/ 1 the fan switches to low speed at
the set point
-20°C~99°C
-20°C~99°C
100~500P
Between -20°C and +20°C
2017/05 - Indice de révision : D - Code : 33491
Default value
0
Value measured
0%
20Min
-1°C
8°C
8Min
1
Measured value
Measured value
Measured value
5°C