4.
Do not touch the plug and / or socket with wet hands
5.
Do not immerse or subject the device to dripping or splashing liquids
6.
For extractor models only use detergents compatible with the suction hose and Rilsan coating
materials.
7.
Do not put in traction or lift the machine by means of the electric cable.
EN
8.
Do not use the device in all situations of uncertainty or anomalies typically, though not
mentioned in this manual
5 M A I N T E N A N C E A N D C L E A N I N G
CAUTION!
1.
At the end of every work session to empty and clean the stainless steel drum.
2.
After each session clean the detergent pump by pulling water into it:
a.
to. enter the intake tube cleaner in the tank containing water and turn on the hot
water switch, press the steam button.
3.
THE OPERATION OF CLEANING MUST BE CARRIED OUT PERIODICALLY ACCORDING TO USE
THE MACHINE AT LEAST ONCE A MONTH.
4.
Clean the filters present on the automatic top tubes water and detergent.
5.
WARNING! Lubricate the steam nozzle in the vicinity of the O-ring with high temperature
silicone grease.
6 T R O U B L E S H O O T I N G
The unit does not
Operation stopped
The suction power
decreases
The suction power
decreases abruptly
The steam doesn't
come out
Error displayed
Water falls from
drain pipe
STEAM POSEIDON – SWI140-SWI220
Instruction Manual
The presence of holes and cuts on the suction filter walls can
allow the passage of materials and can become a cause of
irreparable damage to the appliance.
FAULT
start
The thermal protector of which
some units have intervened
following an overheating
clogged filter, suction hose or
clogged accessories
Limestone in circuit or pump
main thermal protection,
secondary thermal protection,
level, pressure sensor
The safety valve is triggered
because the maximum pressure
CAUSE
No power supply
The tank is full
No water
malfunction
24
REMEDY
Check the power switch, the power
cord
After cooling to turn it back on
Check and clean
Turn off the machine and empty the
tank
Refill water
Bring machine for service
Turn off the machine, wait and then
turn on. If the problem persists call
service.
Turn off the machine, wait and then
turn on. If the problem persists call
service.
REV 00