2.5.1 Recommended System DC and AC Power Consumption (+5VSB)
+5VSB
Efficiency
2.5.2 Low Load Efficiency Requirements depend on Overall PSU Size.
Comment if these values can be increased to lower overall computer power
consumptions at these low loads.
DC Output Rating (W)
2.6 Remote ON/OFF control
When the logic level "PS-ON" is low, the DC outputs are to be enabled.
When the logic level is high or open collector, the DC outputs are to be
disabled.
2.7 Dynamic loading
The PSU is subjected to a load change as shown in the table below at a rate
of 1A/usec (unless otherwise specified).
The frequency of change is set to give the best readability of the deviation and
setting time.
All other output loads and the AC line voltage are chosen in order to obtain the
worst case condition
Output
3.3V
5V
12V
-12V
+5VSB
2.7.1 Duty Cycle Definition
04
45mA
45%
<400W
400W – 500W
>500W
Load
Current slew rate
Caps [μF] (option)
3300
3300
6600
300
3300
90m A
55%
75%
10W Load
>75%
>70%
-
Step Load Size ( Intel )
1A/μs
30% of Max Load
1A/μs
30% of Max Load
Steps from 100%-
5A/us
30% -100%
01A/μs
0.1A/μs
1A
Max Load
75%
2% Load
>70%
Maximum Step Size
200%
-
-
(A)
-
-
-
0.1