ELECTRIC DRYER POWER HOOKUP –
CANADA ONLY
ELECTRICAL REQUIREMENTS
It is your responsibility:
To contact a qualified electrical installer.
■
To be sure that the electrical connection is adequate and in
■
conformance with Canadian Electrical Code, C22.1-latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
■
60 Hz, AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a CSA
■
International Certified Power Cord
intended to be plugged into a standard
14-30R wall receptacle. The cord is
5 ft. (1.52 m) long. Be sure wall receptacle
is within reach of dryer's final location.
8
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
9831317.
For further information, please reference service numbers located
in "Assistance or Service" section of your Use and Care Guide.
For a grounded, cord-connected dryer:
I
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
grounding conductor can result in a risk of electric shock.
Check with a quali ed electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a quali ed electrician.
GAS DRYER POWER HOOKUP –
U.S.A. AND CANADA
ELECTRICAL REQUIREMENTS
120 Volt, 60 Hz, AC only, 15- or 20-amp fused electrical
■
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
4-wire receptacle
(14-30R)
GROUNDING INSTRUCTIONS
Improper connection of the equipment-
SAVE THESE INSTRUCTIONS