Rise RANGER 500/I Manuel D'installation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
4 - Fix the upper flange using the round head screws provided.
Attention: The screw heads must be placed on the upper part of the
flange (inside the case).
This way the foundation case is complete. See figure alongside.
5 -Fit the clamps as in the figure locking them in position with the washer
and the M10 hexagonal head screw. Fold them according to the foundation.
6-Dig a hole in the ground with the dimensions shown in the image to the
side and prepare a proper draining bottom.
Before inserting the foundation case in the excavation run the TEST OF
DRAINAGE.
The TEST OF DRAINAGE is ESSENTIAL to assess the level of permea-
bility of the soil and adopt the most appropriate measures to let the water
that enters into the case to be absorbed in the shortest possible time.
- Pour 40 liters of water into the excavation and wait for 25 minutes.
10 - rev.00
Assembly instructions
gravel
Drainage pipe
Ø 100mm min.
W
VIGILANT / HYDRA 500 / FORCE 525
800x800mm
40 l
RANGER 500
VIGILANT 800 / FORCE 825
W
1000 mm
1100 mm
1400 mm

Publicité