ERROR
4
Connectivity problem
9
Communication failure
between the first
engine and the second
10
Communication failure
11
Abnormal motor
14
Throttle problem
15
16
Anomaly of the motor
19
21
50
53
Overloaded system
55
Temperature too high Temperature too high, wait for the system to cool
ERROR CODE LIST
Description
with the screen
sensor
Brake problem
hall
Second engine
problem
BMS anomaly
Voltage too high
Solving the problem
Check if the circuits are correctly installed or replace
the controller
Check the connection between the 1st controller and
the 2nd controller
Check the connection between the instruments and
that the controller assembly is normal. Turn off the
machine and restart
Check the cable between the controller and the
Motor
Check to see if the throttle is at 0. If it is then the
throttle is normal, disconnect the throttle cable and
restart.
Check the brake at its initial position and at its
maximum, disconnect the brake and restart the
scooter to eliminate the problem
Launch failure, check if the motor is well connected,
if braking occurs replace the motor or the controller
Check if the connection between the 2nd motor is
normally connected, changing the motor or the
controller will correct your problem
Communication problem with the battery
The voltage is too high. Start-up error check if the
voltage is normal, in case of failure change the
battery or the controller
System overloaded, replace controller
down. Otherwise replace the controller.
30