FAULTS
Indicator light "G" (fig. 6) flashes.
Water leaks from head.
Presence of water in oil.
N.B. To reset the indicators on the control panel, rotate (fig. 6) to the "O" position and then to the "I" position.
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
English
CAUSES
No water softener.
Gasket worn.
Oil seal rings worn.
IMPORTANT:
- 14 -
REMEDIES
Fill the tank with water softener.
Call your authorized dealer.
Call your authorized dealer.