- Overvoltage protection
- Undervoltage protection
3.1 Product parameters
Dimension (H x L x W)
Weight
Installation method
Certification
3.2 Input parameters
Recommended cable for the input
terminal
Input wiring
Input rating
Input power limits
Power rating
Grounding
Residual current protection
User Manual
505 mm×402 mm×197 mm
About 9.3kg
Wall mounting/pole mounting
The device has passed the CE certification and meets the requirements of
RED Directive 2014/53/EU and Low Voltage Directive 2014/35/EU and the
following standards:
IEC 61851-1: 2019
IEC 61851-21-2: 2018
EN 300 328 V2.2.2
EN 300 330 V2.1.1
EN 301 908-1 V13.1.1
EN 301 908-2 V13.1.1
EN 301 908-13 V13.1.1
EN 301 511 V12.5.1
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1.1
EN 301 489-17 V3.2.4
EN 301 489-52 V1.1.0
EN 50665:2017 & EN 62311: 2008
5 x 9AWG* (wire gauge 6mm
*It is recommended to crimp the adapter terminals on the power cable
conductor
3P + N for the power circuit
1P + N for the control circuit
380-415 Vac for the power circuit
220-240 Vac for the control circuit
Single-connector, three-phase: maximum: 1 x 22 kW
Dual-connector, three-phase: maximum: 2 x 22 kW
50/60 Hz
TN-S、TT、IT
*Note: The supply circuit must not include a PEN conductor; a PME earthing
facility must not be used as for the protective conductor contact of a charging
point located outdoors.
Type B RCCB
- Grounding detection
- Tilt protection (optional)
2
)
9