Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
The electrical connection must comply
I
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
Wall socket and plug must be accessible at
I
all times.
The appliance should always be earthed. Use
good quality cable for connecting e.g. H05RRF,
1,5 or 2,5 mm
, with 3 cores, depending on the
2
regulations.
With following colour code:
brown =
blue =
green/yellow =
earth (
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection, ensure
that a multi-pole switch with a distance
between contacts of 3 mm is installed in the
supply cable.
The cable must not touch any hot parts
(>70 ˚C),
All manuals and user guides at all-guides.com
phase L
N
)
Replacing the cable
If the cable becomes damaged, replace it as
follows:
Open the junction box (see fig. 13).
I
Unscrew screw "A" from the pull relief.
I
Unscrew the screws from the terminals
I
and remove the cable.
I
Place a new cable of the same type and
length. To connect the cable, see the
colour code for "Electrical connection".
Secure the cable with screw "A" of the pull
I
relief and close the junction box.
fig.13