FUNCTIONING
1 - Control by Internal Ambient Sensor - Temperature control is performed
by equipment's ambient temperature sensor. In this operating mode,
the sensor will also perform Anti Freeze Protection (5 °C) and Thermal
Protection (35 °C).
2 - Control by Internal Ambient Sensor + Floor Temperature Sensor
- Temperature control is performed by the equipment's ambient
temperature sensor while the floor probe will prevent floor overheating/
overcooling, preventing the floor temperature from exceeding the defined
maximum temperature limits (Thermal Protection at 35 °C) and minimum
(Anti-Condensation Protection at 16 °ºC).
When the device is switched ON without a floor probe, it defaults control
mode of "Room sensor without a probe".
At this moment, the LED light flash sequentially (Red-Blue-Red-Blue). If
the floor probe is turned OFF, or if there is a reading interruption, the LED
light starts to flash, indicating the existence of a problem.
12