Télécharger Imprimer la page

Ega Master EGAtronik Manuel D'instructions page 29

Publicité

Les langues disponibles

Les langues disponibles

D.
AC Current
Range
200µA
2mA
20mA
200mA
10A/20A
Remark:
At 10 A range: For continuous measurement ≤10 seconds and interval not less than 15
minutes.
Measurement voltage drop: Full range at 200mV.
Frequency response: 40Hz~400Hz.
Display effective value of sine wave (mean value response).
E. Resistance Test
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
200MΩ
Remark:
Open circuit voltage:
At 200MΩ range: approx. 3V
Other ranges: ≤ 700mV
At 200MΩ range, test lead is in short circuit, and it is normal to display 10 digits. During
measurement, subtract the 10 digits from the reading.
All manuals and user guides at all-guides.com
Resolution
COD. 51255
0.1µA
1µA
10µA
100µA
±(1.8%+3)
10mA
Resolution
COD. 51255
0.1Ω
±(0.8%+3)
1Ω
10Ω
±(0.8%+1)
100Ω
1kΩ
10kΩ
100kΩ
±[5%(reading10)+10]
Accuracy
Overload Protection
±(1%+3)
±(3%+5)
Accuracy
Overload Protection
±(1%+2)
0.315A. 250V
fast type fuse,
Ø5x20mm
Un-fused
250V DC
or AC ms
29