Télécharger Imprimer la page

Danby DDR050BLPBDB-ME Manuel Du Propriétaire page 8

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS
WATER REMOVAL
3. Pump Drain
If the continuous drain is inconvenient, water can be removed from the appliance using the pump drain.
When using the pump, the appliance will first fill the bucket with water and then the pump arm will pump
water from the bucket through the drain and out the hose.
Note that the pump will not completely empty the bucket, it will only remove approximately 20% of the
water from the bucket. Water will remain in the bucket as the pump operates.
When using the pump drain, the water bucket should be emptied every few days to ensure that the water
in the bucket does not become stagnant or grow mildew
Remove the continuous drain hose from the unit and rotate the black plastic cover to the continuous drain
hose outlet clockwise.
Peel off the fixed tape, insert the pump drain hose into the pump drain hose outlet for depth of 15 mm at
least or until it clicks and make sure the hose is secure so there are no leaks.
Direct the other end of the hose to a drain. Press the pump button to activate the pump function. When the
bucket is full, the pump will begin to work.
Ensure that the drain hose is not bent, this can stop the water from draining correctly and overwork the
pump.
Do not connect the provided hose together with another hose. The maximum length of the pump drain hose
should be no more than 4.6 m (15 feet). If the drain hose is too long water may not drain completely which
can lead to stagnant water and mildew build up inside the hose.
To remove the hose, press inward on the ring around the drain and pull the hose outward.
Important: If the drain pump is activated, water will exit the drain whether a hose is attached or not.
Ensure that the drain pump is deactivated when the hose is removed to avoid damage to floor due to
leaking water.
7

Publicité

loading