One-Touch™ Test Mode
To speed up installation and testing, One-Touch™ testing is provided which allows the controller
functionality to be tested at the controller or reader.
Test
Action
Normal Operation
Hold down the One-Touch™
button for less than 2 seconds.
One-Touch™ View
Present keys and press RTE
Mode
switches and observe LEDs.
Automatically exits after 2 minutes
One-Touch™ Active
Hold down the One-Touch™
Mode
button for 2 to 4 seconds.
Present a key to each reader (the
lock will activate).
Reader and Request to
Press the Request to Exit switch
Exit Test
(the lock will activate).
Open the door contact.
Present a key to a reader, press the
Request to Exit switch and open
the door contact simultaneously.
Remove link to 0V on tamper or
open circuit tamper switch.
Auxiliary and Lock
Relays Test
Remove link to 0V on emergency
override or leave open circuit
tamper switch.
Remove the link between TAMP
and 0V on the Tamper & Override
terminal block.
Tamper and Override
Test
Remove the link between OVRD
and 0V on the Tamper & Override
terminal block.
RS-232 Test
Link Tx and Rx on the RS-232
(PAC 512 only)
terminal block.
Hold down the One-Touch™
Leave One-Touch™
button for less than 2 seconds.
Active Test mode
One-Touch™ Test mode will
automatically be timed out after 1
hour and on power down and up.
17474v4.0
All manuals and user guides at all-guides.com
Observation
Controller
Green on -valid key
has been
presented to
reader
Green flash -
invalid key has
been presented to
reader
The appropriate auxiliary relay is activated.
Both auxiliary relay is activated.
The auxiliary relay is activated.
The auxiliary relay is activated but the door relays are uneffected.
Both auxiliary and lock relays are activated, the door opens and the lock operates.
Reader
The green system
status LED flashes
at normal rate.
Door status LEDs
off.
The green system
status LED flashes
at normal rate.
Red on - door open
Yellow on - RTE
switch has been
pressed
The green system
status LED flashes
faster than normal.
The door green
LED flashes once
for SIGA, twice for
SIGB.
The door green
LED flashes three
times and the
yellow LED is lit.
The door green
LED flashes four
times and the red
LED is lit.
The red and
There is no effect at the
green RS-232
reader.
LEDs are lit.
The green
system status
The reader LED returns to
LED returns to
its normal operation.
its normal flash
rate.
The normal operation
of the reader.
The normal operation
of the reader LED
changes, e.g. if
default is red, it turns
green.
The reader LED
flashes once for
SIGA, twice for SIGB.
The reader LED
flashes three times.
The reader LED
flashes four times.
5