TL8100
THERMOSTAT WIRING
1
120 VAC OR 240 VAC
2
2 AMP MAXIMUM INDUCTIVE LOAD
3
TL8100
Fig. 3. Wiring diagram for a line voltage circulator.
ELECTRIC HEATER
1
L
N
2
3
TL8100
Fig. 4. Wiring diagram for a line voltage electric heater.
V4043
L
1
2
3
TL8100
Fig. 5. Wiring diagram for a line voltage valve (V4043 or
similar).
MOTOR
V4044 OR V8044
VALVE OPERATOR
Fig. 6. Wiring diagram for a line voltage 3-wire valve
(V4044 or equivalent); V8044 may be used with 24 VAC
power.
TL8100
1
2
3
1
CONNECT BLACK WIRES ON V8043A AND
YELLOW WIRES ON V8043E.
Fig. 7. Wiring diagram for a 24 VAC 2-wire valve
(V8043A,E or equivalent).
69-2017EFS—03
N
L
L
M29965
G
G
N 120/240 VAC
5 AMP MAXIMUM RESISTIVE LOAD
L
M29966
N
N
120/240 VAC
2 AMP MAXIMUM INDUCTIVE LOAD
L
M29967
TL8100
RED
1
BLUE
2
3
YELLOW
L
N
M29968
V8043A, E
1
R
L
C
N
M29977
TH, TR TH TR
TL8100
1
2
3
Fig. 8. Wiring diagram for a 24 VAC V8043F.
2
R
L
C
N
6
Fig. 9. Wiring diagram for a White Rogers 1311 valve.
1
2
3
TL8100
Fig. 10. Wiring diagram for a 24 VAC furnace or hydronic
zone panel.
Remote Input Wiring
The thermostat has an input for connecting a home
automation system or a remote control system. When a
signal is received at this input, the thermostat switches to
Vacation mode. When the signal is removed, the
thermostat returns to the original mode. See Fig. 11.
TL8100
Fig. 11. Wiring for a home automation system.
2
V8043F
R
L
C
N
M29978
4
5
1
1
3
2
3
TL8100
1311
M29970
R
FURNACE OR
T, T ON PANEL
W
M29971
HOME AUTOMATION
SYSTEM
12 VDC
± 10%
M29972