5. Notes
1. The product must be installed on the ground and the building must be able to support the full
weight of the product filled with water.
2. There should be enough space for maintenance and inspection around the product, and the
electrical junction box and pressure relief valve should be oriented in the direction that is easiest
for maintenance.
3. The connecting pipe should be as short as possible to reduce heat loss.
4. To ensure the best performance of the unit, it is recommended to check the wiring and the water
condition of the unit every 3 months during the operating season, to check if the system has
water shortage.
5. Clean the filter regularly to maintain good water quality. Lack of water and dirty water will affect
the safety and efficiency of the system.
6. In the cold season, the unit must not turn off the power supply, otherwise the water in the water
tank will freeze and damage the water tank;
7. In the case of sufficient water consumption, it is recommended to set the water temperature to
40-45 degrees, which can reduce the heat loss of the water tank, save energy consumption, and
reduce scale generation.
8. It is recommended to carry out the first inspection of the domestic hot water tank anode mag-
nesium rod in 3 to 6 months, and the inspection time of the subsequent interval is determined
according to the actual consumption of the magnesium rod, which is generally once. every 6-12
months. But when it is near the end of consumption, it must be replaced in time, otherwise it is
easy to damage the coating.