THE APPLIANCE HAS VARIOUS PROTECTIONS
1. Frost protection function:
In cooling mode, if the temperature of the evaporator pipe is too low, the machine will go
into the protection state until it reaches the temperature rise of the evaporator pipe
temperature sensor, then the air conditioner will return to operation. normal.
2. Water overflow protection function:
When the water in the water tank exceeds the warning level, an alarm sounds and the
display shows Ft. The appliance must be emptied (see paragraph "Tank full").
3. Automatic defrost:
The air conditioner has the automatic defrost function. After defrosting, the air
conditioner will return to normal operation.
4. Compressor protection:
To increase the service life of the compressor, the compressor has a start-up protection
function of 3 minutes after the compressor is switched off.
CLEANING AND MAINTENANCE :
IMPORTANT: Always unplug the power cord from the power outlet before cleaning or
servicing the machine.
• APPLIANCE MAINTENANCE:
1. Never use corrosive detergents, wire brushes, abrasive scouring pads or metal / sharp
tools to clean your device.
2. Dry the appliance completely after cleaning.
3. Store the device in a cool, dry place out of the reach of children and pets.
4. For all maintenance and cleaning operations, it is IMPERATIVE to unplug the appliance for
safety reasons.
5. Do not use chemicals or detergents for cleaning, which could easily damage or deform
your device.
6. Clean the air conditioner with a slightly damp cloth, then dry it.
• AIR FILTER MAINTENANCE:
-For best efficiency, the air filter should be cleaned after 100 hours of use. Switch off the
appliance and unplug it.
Remove the screens and filters.
Remove dust with a vacuum cleaner
EN-23