Red indicator 'fault' lights.
Red indicator 'fault'
blinks slowly.
'Power' led lights, but the
connected equipment
does not work.
Inverter does not function
at all. All led's are off.
19
Temperature protection
active.
Problem on the output.
Inverter is in sleep mode.
Battery capacity too low to
supply the requested
power.
Weak connection between
battery and inverter.
The cables used are too
thin.
The requested power is
more than the inverter can
deliver.
No input voltage present.
External fuses in battery
cable defective.
Input voltage below the
minimal value.
Input voltage higher than
the maximum value.
Internal defect.
- Check that the fan is working
and that the inverter has
sufficient ventilation possi-
bilities
- High ambient temperature.
Place the inverter in a cooler
environment.
- Reduce the load.
There is a short-circuit or
overload. Check the consumers
on faults and the height of the
total load. When the problem
has been resolved, the inverter
will restart automatically.
Inverter will operate automa-
tically when load is high
enough. If necessary, adjust
the setting via the App.
Connect a higher capacity
battery (set).
Check all connections and
cables.
Mount cables matching the
length and capacity.
Check the consumption of the
connected equipment. Make
sure that this falls within the
specifications of the inverter.
Check the connections between
battery and inverter.
Replace the fuses (only
equivalent values)
Battery voltage too low or
battery defective.
- Check if the system-voltage
matches with the inverter.
- Check the system on DC
power supplies that give a too
high voltage.
When after checking the total
system the inverter still doesn't
work, it can be send back for
repair.