Information for the measurement
To obtain the most accurate measurement possible, place the
cable between the tong jaws as far as possible in the
intersection of the marks.
If the position of the cable is not accurate within the tongs, the
measurement error is a maximum of 1.5 %.
Accuracy:
(% of the read-out value + number of digits) at 18° to 28 °C
(64° to 74 °F) and rel. humidity < 75 %.
AC (automatic range selection)
Measuring
range
60 A
600 A
Frequency response: 40-200 Hz
Maximum input current: 600 A AC
Minimum input current: 1.5 A AC
INRUSH measurement
In the measurement range A~, press the button "SEL", "INRUSH"
appears on the display.
The display indicates "----" until the motor, or similar, is switched
on.
The value is displayed and retained, this measurement is only
carried out once.
After the measurement, keep the "SEL" button pressed, to
change to the normal measurement mode, by again pressing,
returns to the inrush measurement.
®
Testboy
TV 216N
Information for the measurement
Resolution
0.01 A
0.1 A
Tolerance
± 3.0 % + 10 digit
49