H-9832
SLIM FLOW
EYEWASH STATION
WARNING! Failure to comply with these
instructions may result in serious personal injury,
serious illness, blindness or death.
• The Slim Flow must be level for proper operation.
• The unit may weigh over 80 lbs. when filled
with solution. Assistance may be required when
installing unit on the hanging bracket.
• Employees must be instructed in the use of
emergency eyewash stations.
• This unit is intended for emergency use by victims
of eye contamination until medical treatment
LOCATION
The ANSI Standard Z358.1-2014 requires that:
1. The Slim Flow should be positioned with the nozzle(s)
no less than 33" and no greater than 45" from
the floor and 6" minimum from the wall or nearest
obstruction.
2. Eyewash units should be in accessible locations
that require no more than 10 seconds to reach. The
eyewash should be located on the same level as
the hazard, and the path of travel should be free of
obstructions that may inhibit the immediate use of
the equipment. For a strong acid or a strong caustic,
the eyewash should be immediately adjacent to the
hazard.
3. Each eyewash location should be identified with a
highly visible sign positioned so the sign is visible
within the area served by the eyewash. The area
around the eyewash should be well-lit.
PAGE 1 OF 6
1-800-295-5510
uline.com
SAFETY
• An individual or department must be assigned the
• The use of water preservative is recommended
• Use of a fluid beyond the expiration date may
INSTALLATION
4. The eyewash station must be installed in an easily
The Slim Flow may be placed on any level surface of
required height, such as a table or bench. Allow for
proper drainage and disposal of the flushing solution.
The unit may also be mounted on a wall or post using
the metal hanging bracket. The unit must be level for
proper operation.
Pour le français, consulter les pages 5-6.
is obtained. In all cases, the victim should seek
medical attention immediately after flushing.
task of checking all self-contained eyewash units
on a weekly basis.
with this eyewash station to prevent the growth of
harmful bacteria in the eyewash tank.
result in serious personal injury.
accessible location in the immediate area of
hazard to the employee.
Para Español, vea páginas 3-4.
0323 IH-9832