Télécharger Imprimer la page

Carrier LOWBOY 098 Serie Instructions D'installation page 2

Fournaise au mazout, puissance de l'entrée 77,000 - 98,000

Publicité

Les langues disponibles

Les langues disponibles

TABLE OF CONTENTS
1.
SAFETY REGULATIONS............................................... 3
1.1
SAFETY LABELING AND WARNING SIGNS ................ 3
1.2
IMPORTANT INFORMATION ........................................ 3
1.3
DETECTION SYSTEMS ................................................ 3
1.4
DANGER OF FREEZING ............................................... 3
2
INSTALLATION ............................................................. 4
2.1
POSITIONING THE FURNACE ..................................... 4
2.1.1
Installation in an enclosure ............................................. 4
2.2
ELECTRICAL SYSTEM ................................................. 4
2.3
installation of the thermostat .......................................... 4
2.4
INSTALLATION OF THE BURNER ................................ 5
2.4.1
Nozzles .......................................................................... 5
2.4.2
Air and Turbulator Settings ............................................. 5
2.4.3
Post purge delay adjustment .......................................... 5
2.5
VENTING ....................................................................... 5
2.5.1
Masonry chimney ........................................................... 5
2.5.2
Factory Built Chimneys .................................................. 5
2.5.3
Draft Regulator ............................................................... 5
2.5.4
Side-Wall Venting .......................................................... 5
2.6
BLOCKED VENT SHUT-OFF DEVICE (BVSO) FOR
CHIMNEY VENTING ...................................................... 6
2.6.1
BVSO Performance Test ................................................ 6
2.7
COMBUSTION AIR SUPPLY AND VENTILATION ........ 6
2.7.1
Contaminated Combustion Air ....................................... 6
2.7.2
Burner with Outdoor Combustion Air Kit ......................... 6
2.8
OIL TANK ...................................................................... 6
2.9
DUCTING ....................................................................... 7
2.9.1
Air filter ........................................................................... 7
2.9.2
Supply air adjustment (4 speed motor) ........................... 7
2.9.3
Supply air adjustment (ecm variable speed motors) ....... 7
2.10
INSTALLATION OF ACCESSORIES ............................. 8
2.10.1
Humidifier (HUM) ........................................................... 8
2.10.2
Electronic Air Cleaner (EAC) .......................................... 8
2.10.3
Air Conditioner (or Heat Pump) ...................................... 8
3
OPERATION .................................................................. 9
3.1
START-UP ..................................................................... 9
3.2
OPERATING SEQUENCE OIL HEATING MODE .......... 9
3.3
CHECKS AND ADJUSTMENTS .................................... 9
3.3.1
Purging the oil line .......................................................... 9
3.3.2
Pressure adjustment ...................................................... 9
3.3.3
Combustion Check ......................................................... 9
3.3.4
Draft Regulator adjustment ............................................ 9
3.3.5
Overfire pressure test ..................................................... 9
3.3.6
Vent Temperature Test .................................................. 9
3.3.7
Supply air Temperature Rise Test ................................ 10
3.3.8
Limit Control Check ...................................................... 10
3.3.9
Restart after burner failure ........................................... 10
4
MAINTENANCE ........................................................... 11
4.1
CLEANING THE HEAT EXCHANGER ......................... 11
4.2
CLEANING THE BLOCKED VENT SHUT-OFF DEVICE
(BVSO) ........................................................................ 11
4.3
CLEANING OF THE BURNER HEAD .......................... 11
4.4
REPLACING THE NOZZLE ......................................... 11
4.5
REPLACING THE OIL FILTER .................................... 11
4.6
REPLACING THE AIR FILTER .................................... 11
5
FURNACE INFORMATION .......................................... 12
6
DIMENSIONS AND RATINGS ..................................... 13
7
COMPONENTS AND PARTS LIST .............................. 18
TABLE OF TABLES
Table 1:
Blower speed adjustments (heating mode, 4 speed
motor) ...................................................................... 7
Table 2:
Blower speed adjustments (A/C mode, 4 speed
motor) ...................................................................... 7
Table 3:
Heating Mode .......................................................... 7
Table 4:
Air Conditioning Mode .............................................. 7
Table 5:
CFM adjustment - All Modes .................................... 7
Table 6:
Delay adjustments - Heating Mode .......................... 7
Table 7:
Technical Specifications ........................................ 13
Table 8:
Airflow Data, Models with 1/3 HP PSC motors ....... 14
Table 9:
Airflow Data, Models with 1/2 HP ECM motors ...... 14
Table 10:
Minimum clearances from combustible material .... 15
Table 11:
Parts List - With 4 Speed motor PSC ..................... 19
Table 12:
Parts List - With variable speed motor ECM .......... 21
TABLE OF FIGURES
Figure 1:
Location and dimensions of ventilation air openings
in a closet door ........................................................ 4
Figure 2:
Heating & Air Conditioning - With 4 Speed Motor..... 5
Figure 3:
Thermostat Wiring- Heating & Air Conditioning - With
ECM Variable Speed Motor ..................................... 5
Figure 4:
Thermostat Wiring-Heating &Air
Conditioning/HeatPump - With ECM Variable Speed
Motor ....................................................................... 5
Figure 5:
Blower start / stop delays - Board #1158 .................. 7
Figure 6:
Furnace Dimensions .............................................. 15
Figure 7:
Wiring Diagram - 4 Speed Motor (PSC) ................. 16
Figure 8:
Wiring Diagram - Variable Speed Motor (ECM) ...... 17
Figure 9:
Parts List - With 4 Speed motor PSC ..................... 18
Figure 10:
Parts List - With variable speed motor ECM .......... 20
2

Publicité

loading

Ce manuel est également adapté pour:

Lowboy obl098Lowboy ovl098