Security Light with
Motion-Activated
Sensor
Models 52-4042-2 / 52-4041-4
Features
• Turns on lighting when motion is detected.
• On-Time control allows length of time light stays on
to be adjusted.
• Photocell keeps light off during daylight hours.
• LED flashes day or night to indicate motion has been
detected.
This package includes:
Lamp
Holders
Cover
Plate
Light Control
Mounting Bolt
Mounting Strap
6 Screws
(3 sizes included)
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2008 HeathCo LLC
Rubber Plug
Plastic Hanger
Sensor
2 Wire
Connectors
Gasket
OPERATION
Mode:
On-Time
Test
5 Seconds
Auto
1, 5, or 10 Minutes
Manual
To Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the
1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day
x
/
minutes for
1
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
598-1198-01
Night
x
x
x

Publicité

loading

Sommaire des Matières pour NOMA 52-4042-2

  • Page 1 Sensor the circuitry to calibrate. TEST ON-TIME Models 52-4042-2 / 52-4041-4 Put the ON-TIME switch on the bottom of the sensor in the TEST position. 10 5 1 TEST Features • Turns on lighting when motion is detected.
  • Page 2 INSTALLATION ❒ Route the light control’s wires through the large gasket holes. For easy installation, select an existing light with a wall ❒ Twist the junction box wires and fixture wires together switch for replacement. as shown. Secure with wire connectors. Mounting White to Black to...
  • Page 3 on, wait 1 minutes. TEST AND ADJUSTMENT ❒ Loosen the clamp screw in the Clamp sensor ball joint and gently Screw ❒ Turn on the circuit breaker and light switch. rotate the sensor. ❒ Walk through the coverage NOTE: Sensor has a 1 minute warm up period Ball area noting where you are...
  • Page 4 TROUBLESHOOTING GUIDE If you experience a problem, follow this guide. SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not come Lights stay on 1. Light switch is turned off. 1. A floodlight is positioned too close to 2. Floodlight is loose or burned out. continuously.
  • Page 5 Auchoix, amanecer* de mouvement * Revient au mode automatique au lever du soleil. Note: Après mise en circuit, attendre enfiron minute pour que l’étalonnage du circuit soit Modèles 52-4042-2 / 52-4041-4 complété. ESSAI ON-TIME Amener en position d’essai (TEST) Caractéristiques l’interrupteur de temps en circuit (ON-...
  • Page 6 INSTALLATION ❒ Faire passer les fils de la commande d'éclairage par le trou de la garniture. Pour faciliter l’installation, choisir un appareil d’éclairage ❒ Torsader les fils de la boîte de jonction avec ceux devant être remplacé et qui est déjà commandé par de la commande d’éclairage.
  • Page 7 ESSAIS ET RÉGLAGES ❒ Desserrer la vis de blocage Vis de de la rotule et faire pivoter le blocage ❒ Mettre en circuit le disjoncteur et l’interrupteur détecteur pour pointer. d’éclairage. ❒ Marcher dans la zone de Rotule couverture et noter à quel en- NOTE: Le capteur doit se réchauffer 1 minute avant droit l’éclairage se déclenche.
  • Page 8 GUIDE DE DÉPANNAGE Si vous éprouvez des difficultés, suivre ce guide. SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE L’éclairage ne 1. L’interrupteur d’éclairage est hors L’éclairage 1. Un projecteur est situé trop près du s’allume pas. tension. reste allumé détecteur ou pointé vers des objets continuellement.

Ce manuel est également adapté pour:

52-4041-4