Page 1
All manuals and user guides at all-guides.com SERVICE MANUAL MODEL TYPE: ES700P LS701P WEB ACCESS: http://www.yorkville.com WORLD HEADQUARTERS CANADA U.S.A. Yorkville Sound Yorkville Sound Inc. 550 Granite Court 4625 Witmer Industrial Estate Pickering, Ontario Niagara Falls, New York L1W-3Y8 CANADA...
Page 2
All manuals and user guides at all-guides.com IMPORTANT SAFETY INSTRUCTIONS This lightning flash with arrowhead symbol, within The exclamation point within an equilatereal triangle is an equilateral triangle, is intended to alert the user to intended to alert the user to the presence of important the presence of uninsulated “dangerous voltage”...
Page 3
GND AT TRANSISTORS troubleshooting of Level Shift, drivers OUTPUT OUTPUT and output devices INPUT FILTER INTEGRATED DIFF AMP ERROR AMP U9. Q8, U10 GATE DRIVE LEVEL SHIFT -120 WOOFER RAMP GENERATOR SILENT ON/OFF VIA Q19 WOOFER BLOCK-DIAG-LS701P-00-1v0...
Page 4
1/4W P6:A U24:A 200V +15VIP P6:C IGND 17K40 Function INSERT FOR LS720P 0.1% 1/4W GNDA GNDA 0.1% 220K DNS FOR LS701P TL072 100N -15V NET00227 NET00227 IN-Speaker OUT-Line MINI DNS FOR LS720P 4010 TL072 NET00143 +15VIP U17:A INSERT FOR LS701P...
Page 5
All manuals and user guides at all-guides.com M1485.PCB_DATABASE_HISTORY MODEL(S):- LS701P +15V +15V DATE VER# DESCRIPTION OF CHANGE R210 +22V 1/4W MARCH 2010 1.00 MADE FROM NX720S M1330 V1.00 IN MARCH 2010 FORCE UPDATED PARTS TONY'S LIST APRIL 2010. FUSIBLE JUNE 2010 2.00...
Page 7
5. PCBSA CHECK HEATSPREADER #Z1258 FOR SMOOTH SURFACES 6. LEDS ARE INSERTED IN PCBSA WITH A #4007 SPACER 7. Make sure Jumper X2 is not stuffed for LS701P. ***PCBSA****** 8. C4 #5194-470P 1000V 10%CAP BLK RAD CER.2in GETS HAND INSERTED AND RTV IN PCBSA.