14
PD30EM & PD40EM Installation and User manual
Recommended lock cases for the PD40EM
PD40EM is suitable for most doors with e g ASSA Euro locks. Check
suitability by simply measuring your own lock. The distance between the
centre of the handle and the centre of the cylinder should be 72 mm and
the handle fixing holes 38 mm. The backset should normally be 55 or 60
mm (but are normally not critical for PD40EM).
The PD40EM can be used with many types of locks, like e g ASSA 8720
If in doubt please check with your local locksmith.
Basic needs are the following:
The distance between the centre of the handle and the centre of the
cylinder should be 72 mm.
The handle must have an 8 mm square spindle.
The handles fixing holes 38 mm.
NoTE! PD40EM is only for internal fitting and operation and should
neither be specified for back to back installation.
All manuals and user guides at all-guides.com
38 mm
55/60 mm
88/93 mm
72 mm