MENU
PARAm
Functioning of the auxiliary light
OFF: functioning of courtesy light: the light activates further a command and stays
lit for all the motion period, going off after a time set by the function coURT.
couRL
ON:
functioning light zone, the light activates at the beginning of the motion.
The counting of the switching off time set by the function coURT starts once
that the gate reaches the position of complete closing.
Switching off of the auxiliary light.
couRT
The time of the switching off of the auxiliary light can be set from 1 second till 300
seconds.
Clock time.
OFF: disabled function
cLoc
ON:
enabling the function a time relay can be connected ( free contact timer) at
the input open.
The function is disabled in case the dead man function is enabled.
5. Faults diagnostics
The control unit indicates anomalies or malfunctions of the system through a message that appears on the display of the control unit.
In particular the faults are codified as follows:
Fault intervention motor protector. The control unit has detected an absorption higher than the one set by the menu (see entry MOTS
err1
of paragraph 4.3) for a period longer than 3 seconds. Check that ther are not anomalies in the system. In case that there are
problems in the installation, increase the threshold of the motor protector being careful to not overpass the absorption values of given
by the motor's constructor.
Fault lack of phase (only wiht three-phase functioning). The control unit has detected an unbalancing between the phases higher
err2
than 40%.
Fault of motor thermal. To use the automation again leave the motor still until the alarm ceases.
err3
Power supply
Photocells power supply
Acessories power supply
Motor output
Flashing light output
Courtesy light output
Auxiliary function output ( only with card R1).
Dry contact output, NOT powered.
WARRANTY - In compliance with legislation, the manufacturer's warranty is valid from the date stamped on the product and is restricted to the
repairor free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The
warranty does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused by
environmentalinterference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by our
defective products, are only those responsibilities that come under Italian law.
6-1622598
REV.2
20/04/2016
All manuals and user guides at all-guides.com
DESCRIPTION
TECHNICAL FEATURES - CT3IND CONTROL UNIT
230 Vac +-10%, 50Hz singlephase / 400 Vac 50Hz Three-phase
24 Vdc 3W MAX
24 Vac 3W MAX
230Vac single phase 800W Max, 400 Vac THREE-PHASE 1,5KW Max (current limited to
10A), cosΦ > 0.8
230 Vac 60W MAX for fix light , without self blinking
230Vac 100W MAX
230Vac 5A Max, 30Vdc 5A Max
ALLMATIC S.r.l
32020 Lentiai - Belluno – Italy
Via dell-Artigiano, n° 1 – Z.A.
Tel. 0437 751175 – 751163 r.a.
http://www.allmatic.com - E-mail: info@allmatic.com
ITA
ENG
SELECTABLE VALUES
Fax 0437 751065
FRA
ESP
DEU
POR
DEFAULT
min-max
ON — OFF
OFF
1 (s) — 300 (s)
60 (s)
ON — OFF
OFF
MEMO
9 / 9