INSTALLATION
MMS control box is solely designed for interior
use. It is appropriate to situate it on an inter-
nal wall at about 1,5 m above the floor in the
room. Do not install above a heat source (TV,
heater, fridge, etc.) or under direct sun light, in
draught, radiation of devices nor in humid en-
Fig. 2: Connection diagram of the MONZUN heater with the MMS control box
Control of multiple MONZUN heaters in one zone
The control box MMS+OMM3(OMM6) can
control up to 3 (6) MONZUN heaters.
On the OMM box, each connected MONZUN
can be turned off, switched to automatic
vironment. Install the MHS control box using
enclosed screws and dowels in a chosen place.
Pass cable through a gland on the lower side
or through holes in box rear side and connect
in the terminal board pursuant to the Fig. 2.
mode or turned on manually. In automatic
mode, the radiators are controlled by the regu-
lator, in manual mode they heat until they are
turned off manually.
®